A handrail or grab bar and any wall or other surface adjacent to it shall be free of any sharp or abrasive elements. Edges shall have a minimum radius of 1/8 in (3.2 mm)....
Search Results "Handrail Fitting"
-
4.26.4 ELIMINATING HAZARDS
-
§ 38.97(c)
(c) At entrances equipped with steps, handrails or stanchions shall be provided in the entrance to the car in a configuration which allows passengers to grasp such assists from outside the...
-
11B-1005.2.1 Height
At least 25 percent of the railings, guards, or handrails shall be 34 inches (864 mm) maximum above the ground or deck surface....
-
11B-1005.2.1 Height
At least 25 percent of the railings, guards, or handrails shall be 34 inches (864 mm) maximum above the ground or deck surface....
-
T303.2 Edges
Edges shall be rounded or eased.
-
11B-1008.2.5.3.1 Handrail gripping surfaces
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 0.95 inch (24 mm) minimum and 1.55 inches (39 mm) maximum....
-
1. Transfer Supports
located within reach of the transfer surface and not obstruct transfer, be capable of resisting vertical and horizontal forces of 250 pounds applied to all points, and not rotate in their fittings...
-
11B-1008.2.5.3.1 Handrail gripping surfaces
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 0.95 inch (24 mm) minimum and 1.55 inches (39 mm) maximum....
-
11B-1008.2.5.3.1 Handrail gripping surfaces
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 0.95 inch (24 mm) minimum and 1.55 inches (39 mm) maximum....
-
Question 20
Is the required floor and wall space inside public restrooms and fitting rooms blocked by obstacles such as trash cans, chairs, or shelving?...
-
M305.2.3 Fittings
Transfer supports shall not rotate within their fittings....
-
Circular Cross Section and Clearance (§505.5, §505.7)
Circular Cross Section and Clearance
-
M305.2.8 Fittings
Transfer supports shall not rotate within their fittings when in place for transfer....
-
Door Swing: ADA Standard Section 803.3
Doors shall not swing into the room unless a clear floor or ground space complying with 305.3 is provided beyond the arc of the door swing.
-
11B-803.3 Door swing
Doors shall not swing into the room unless a turning space complying with Section 11B-304.3 is provided beyond the arc of the door swing.
-
11B-803.3 Door swing
Doors shall not swing into the room unless a turning space complying with Section 11B-304.3 is provided beyond the arc of the door swing.
-
Aisle Ramps in Assembly Areas
In assembly areas, aisle ramps required to be accessible are exempt from some handrail requirements....
-
§ 38.155 Interior circulation, handrails and stanchions
[See subsections ...]
-
Landings [§405.7]
Handrails, edge protection, vertical posts and other elements cannot obstruct or overlap the minimum 60” by 60” clearance....
-
§ 38.29(d)
(d) Handrails and stanchions shall be sufficient to permit safe boarding, on-board circulation, seating and standing assistance, and alighting by persons with disabilities....
-
§ 38.29(a)
(a) Interior handrails and stanchions shall permit sufficient turning and maneuvering space for wheelchairs and other mobility aids to reach a securement location from the lift or ramp....
-
11B-803.6 Mirrors
Mirrors shall be installed with the bottom edge of the reflecting surface 20 inches (508 mm) maximum above the finish floor or ground. Mirrors shall be full length with a reflective...
-
11B-803.5 Coat hooks and shelves
Coat hooks provided within the room shall be located within one of the reach ranges specified in Section 11B-308. Shelves shall be 40 inches (1016 mm) minimum and 48 inches (1219 mm)...