[See subsections ...]
Search Results "Handrail Clearance"
-
11B-306 Knee and toe clearance
-
305.7 Maneuvering Clearance
Where a clear floor or ground space is located in an alcove or otherwise confined on all or part of three sides, additional maneuvering clearance shall be provided in accordance with 305.7.1...
-
11B-305.7 Maneuvering clearance
Where a clear floor or ground space is located in an alcove or otherwise confined on all or part of three sides, additional maneuvering clearance shall be provided in accordance with Sections...
-
11B-305.7 Maneuvering clearance
Where a clear floor or ground space is located in an alcove or otherwise confined on all or part of three sides, additional maneuvering clearance shall be provided in accordance with Sections...
-
4.4 Knee and Toe Clearances
4.4 Knee and Toe Clearances Knee and toe clearances of the four sets of standards are roughly comparable....
-
4.13.6 MANEUVERING CLEARANCES AT DOORS
Minimum maneuvering clearances at doors that are not automatic or power-assisted shall be as shown in Fig. 25....
-
R409.6 Gripping Surface
Handrail gripping surfaces shall be continuous along their length and shall not be obstructed along their tops or sides....
-
T207.1 General
Non-rail vehicles shall provide handrails, stanchions, and handholds in accordance with T207. Handrails, stanchions, and handholds shall comply with T303....
-
11B-812.4 Vertical clearance
Vehicle spaces, access aisles serving them, and vehicular routes serving them shall provide a vertical clearance of 98 inches (2489 mm) minimum....
-
11B-812.4 Vertical clearance
Vehicle spaces, access aisles serving them, and vehicular routes serving them shall provide a vertical clearance of 98 inches (2489 mm) minimum....
-
§ 38.77(b)
(b) At entrances equipped with steps, handrails and stanchions shall be provided in the entrance to the vehicle in a configuration which allows passengers to grasp such assists from outside...
-
Section 4.26.4
• Section 4.26.4 of the 1991 Standards requires handrail gripping surfaces to have edges with a minimum radius of 1/8 inch....
-
4.13.6 Maneuvering Clearances at Doors
Minimum maneuvering clearances at doors that are not automatic or power-assisted shall be as shown in Fig. 25....
- Figure 404.2.4.3(c) Maneuvering Clearance at Recessed Doors and Gates – Drawing from the U.S. Access Board
- Figure 404.2.4.3(b) Maneuvering Clearance at Recessed Doors and Gates – Drawing from the U.S. Access Board
-
11B-307.4 Vertical clearance
Vertical clearance shall be 80 inches (2032 mm) high minimum. Guardrails or other barriers shall be provided where the vertical clearance is less than 80 inches (2032 mm) high....
-
11B-307.4 Vertical clearance
Vertical clearance shall be 80 inches (2032 mm) high minimum. Guardrails or other barriers shall be provided where the vertical clearance is less than 80 inches (2032 mm) high....
-
Ramps
Provide handrails on each side of the ramps at the following locations:...
-
Minimum Required Depth: ADA Standard Section 306.3.3
Section 306.3.3 covers the current ADA Standards for the minimum required depth for knee clearance.
-
Knee and Toe Clearance
Accessible lavatories and sinks must provide knee and toe clearance for a forward approach (606.2)....
-
Maximum Depth: ADA Standard Section 306.2.2
Section 306.2.2 covers the current ADA Standards for the maximum depth for toe clearance.
-
Maneuvering Clearances [§404.2.4]
Maneuvering Clearances [§404.2.4] Required maneuvering clearances provide space for opening and proceeding through doors, doorways, and gates using wheelchairs and other mobility aids...
-
T207.3 Fare Collection Devices
Handrails shall be provided at fare collection devices and shall be configured so that they can be used for support when at the fare collection device....