Where a required exit from an occupiable level above or below a level of accessible exit discharge is not accessible, an area of rescue assistance shall be provided on each such level (in...
Search Results "Approach Enter Exit"
-
207 Accessible Means of Egress
- 309.3 Baby Changing Table Pull Down Handle Height
-
Re: Section 307 Protruding Objects
The more blatant inconsistency is the lavatory, which is required to be 17" deep minimum due to the required forward approach clear floor/knee and toe space, and must provide knee clearance...
-
General: ADA Standard Section 703.1
Signs shall comply with 703. Where both visual and tactile characters are required, either one sign with both visual and tactile characters, or two separate signs, one with visual,...
-
Style: ADA Standard Section 703.5.3
Characters shall be conventional in form. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms.
-
Height from Finish Floor or Ground: ADA Standard Section 703.5.6
Visual characters shall be 40 inches (1015 mm) minimum above the finish floor or ground. EXCEPTION: Visual characters indicating elevator car controls shall not be required to...
-
11B-703.1 General
Signs shall comply with Section 11B-703. Where both visual and tactile characters are required, either one sign with both visual and tactile characters, or two separate signs, one...
-
11B-703.5.3 Style
Characters shall be conventional in form. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms.
-
11B-703.1 General
Signs shall comply with Section 11B-703. Where both visual and tactile characters are required, either one sign with both visual and tactile characters, or two separate signs, one...
-
11B-703.5.3 Style
Characters shall be conventional in form. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms.
-
Location: ADA Standard Section 703.4.2
Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side. Where a tactile sign is provided at double doors with one active leaf, the...
-
General: ADA Standard Section 216.1
Section 216.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for signs.
-
Knee and Toe Space [§305.4 and §306]
Knee and toe space allows a closer approach to elements and reduces the reach to operable parts....
-
4.30.6 Mounting Location and Height
Mounting location for such signage shall be so that a person may approach within 3 in (76 mm) of signage without encountering protruding objects or standing within the swing of a door....
-
1007.4 Elevators
The elevator shall be accessed from either an area of refuge complying with Section 1007.6 or a horizontal exit....
- Figure 703.4.2 Location of Tactile Signs at Doors – Drawing from the U.S. Access Board
-
Signage Requirements in the 2010 Standards for Accessible Design
The purpose of the SEGD 2012 ADA White Paper Update is to help the EGD community meet the spirit and intent of the new SAD accessible guidelines.
-
1003.2.13 Accessible means of egress
Section 1003.2.13 Change to read as shown: (E19-00 & E20-00) 1003.2.13 Accessible means of egress. Accessible means of egress shall comply with Sections 1003.2.13.1 through...
-
1132A.5.1 General
The floor or landing on the dwelling unit side of the primary entry door and any required exit door shall have a minimum length of not less than 44 inches (1118 mm)....
-
Signage
Mounting location for such signage shall be so that a person may approach within 3 in (76 mm) of signage without encountering protruding objects or standing within the swing of a door....
-
Re: Section 307 Protruding Objects
Yes, it is a protruding object hazard based solely on section 307, but so is the (code compliant) lavatory with its (required) 29" high front edge, and the 8" deep (code compliant)...
-
Section 307 Protruding Objects
This dryer protrudes more than 4" from the wall and is greater than 27" above the finish floor. Isn't this a violation of Section 307 Protruding Objects?