Space must be available for a close approach outside the swing of doors. It is important that fixed elements (e.g., drinking fountains) and furnishings not obstruct the approach....
Search Results "Approach Enter Exit"
Commonly Searched Documents
-
Mounting Location and Height [4.30.6]
-
1009.3 Stairways
Exit access stairways that connect levels in the same story are not permitted as part an accessible means of egress....
-
Check-Out Aisles and Sales and Service Counters
The 2010 Standards specify different lengths for the accessible portion of sales and service counters based on the type of approach provided....
- Behavioral Safety Products #TC230 Suicide Resistant Standard Trap Cover
- McGuire Manufacturing Co., Inc. 155CRSWC: Offset Lavatory Strainer with Chain and Rubber Stopper
-
1009.3 Stairways
[DSA·AC & HCD 1.AC] In addition, exit stairways shall comply with Chapter 11A, Sections 1115A and 1123A, or Chapter 11B, Sections 11B-210 and 11B-504, as applicable....
-
Character Proportions: ADA Standard Section 703.5.4
Characters shall be selected from fonts where the width of the uppercase letter “O” is 55 percent minimum and 110 percent maximum of the height of the uppercase letter “I”.
-
Character Spacing: ADA Standard Section 703.5.8
Character spacing shall be measured between the two closest points of adjacent characters, excluding word spaces. Spacing between individual characters shall be 10 percent minimum...
-
11B-703.5.4 Character proportions
Characters shall be selected from fonts where the width of the uppercase letter “O” is 60 percent minimum and 110 percent maximum of the height of the uppercase letter “I”. [2010...
-
11B-703.5.8 Character spacing
Character spacing shall be measured between the two closest points of adjacent characters, excluding word spaces. Spacing between individual characters shall be 10 percent minimum...
-
Re: 404.2.4.3 Recessed Doors and Gates
Notice that the text does not match the figure for a push approach door. This may be an error in the Standards, but since the text governs, it exceeds the illustrated requirement. ...
-
Permanent Rooms and Spaces
Section 216.2 covers designations of permanent rooms and spaces, including pictograms provided as part of such signs. These types of signs are required to be tactile through the...
-
1007.6.2 Separation
Each area of refuge shall be separated from the remainder of the story by a smoke barrier complying with Section 709. Each area of refuge shall be designed to minimize the intrusion...
-
1003.2.13.5.2 Separation
Each area of refuge shall be separated from the remainder of the story by a smoke barrier complying with Section 709. Each area of refuge shall be designed to minimize the intrusion...
-
B. Braille Signs
B. Do the wall mounted signs provided for the rooms listed above have Braille and raised letters so that they can be read by persons who are blind or have low vision? [ADA Stds....
-
1009.4 Elevators
In order to be considered part of an accessible means of egress, an elevator shall comply with Sections 1009.4.1 and 1009.4.2.
-
Knee and Toe Space [§305.4 and §306]
Knee and toe space allows a closer approach to elements and reduces the reach to operable parts....
-
11B-216.2 Designations
Tactile exit signs complying with Chapter 10 contribute to a safe environment for people with visual impairments. ◼...
-
1002.1 Definitions
EXIT. GUARD ([DSA-AC, HCD 1 & HCD 2] or GUARDRAIL). HANDRAIL. MEANS OF EGRESS PUBLIC WAY. STAIR. STAIRWAY. WINDER...
- 309.3 Baby Changing Table Pull Down Handle Height
-
1002.1 Definitions
EXIT. GUARD ([DSA-AC, HCD 1, HCD 2 & HCD 1-AC] or GUARDRAIL). HANDRAIL. MEANS OF EGRESS PUBLIC WAY. STAIR. STAIRWAY. WINDER...
-
Exception for accessible means of egress in existing buildings in IBC 2000
1003.2.13 Accessible means of egress. Accessible means of egress shall comply with Sections 1003.2.13.1 through 1003.2.13.7.1. Accessible spaces shall be provided with not less...