Specifications are provided for the counter surface height of check-out aisles, including the height of counter edge protection, which is limited to 2 inches above the counter surface (904.3.2...
Search Results "Door Surface"
Commonly Searched Documents
-
904 Sales and Service Counters
-
What other considerations are significant for persons with disabilities?
Thus, walks surfaced in these materials could not constitute an accessible route....
-
Questionnaire Data
Table 7 displays the results from the surface questionnaire for all surfaces....
-
11B-602.9 Pedestrian protection
When used, wing walls or barriers shall project horizontally at least as far as the drinking fountain and to within 6 inches (152 mm) vertically from the floor or ground surface....
-
Manual vs. Power (Questionnaire Data)
It should be noted that even though manual WC users had higher vibrations for all engineered surfaces, on average they rated all surfaces better than power chair users....
-
Do basements count in determining a facility’s story count?
As defined in the Standards, a “story” pertains to those portions of buildings “designed for human occupancy included between the upper surface of a floor and upper surface of the floor...
-
DETECTABLE WARNING
A standardized surface feature built in or applied to walking surfaces or other elements to warn of hazards on a circulation path. Advisory Definition of DETECTABLE WARNING....
-
§ 36.401(b)(2)
portion of the residence covered under paragraph (b)(1) of this section extends to those elements used to enter the commercial facility, including the homeowner´s front sidewalk, if any, the door...
-
1013.4, Item 5
Each exit door through a horizontal exit that is required to comply with Section 1013.1 shall be identified by a sign with the words, “TO EXIT.” ...
-
Expert Report of John Rife Torkelson, theACCESSpartnership, L.P. (August 8, 2018)
Building Entrance: One side of the double leaf doors at the designated accessible entrance does not provide at least 32 inches clear passage width when the door is open 90 degrees (1991...
-
COMPARISON OF OBJECTIVE MEASURES AND ENERGY COSTS
COMPARISON OF OBJECTIVE MEASURES AND ENERGY COSTS Objective measures of surface firmness and stability were compared to energy costs (energy consumption, velocity, RPE and level of difficulty...
-
11B-809.9.2 Clear width
Kitchens shall have a minimum clear width measured between any cabinet, work surface or the face of any appliance (excluding handles and controls) and the opposing cabinet, work surface,...
-
¾ Inch Minus Limestone
After the same two days of uncharacteristically heavy rainfall (as noted in the ¼ inch minus segment), the surface had evidence of water pooling on the surface, as there were lines of pine...
- AbleThrive
-
11B-903.4 Back support
Back support shall be 48 inches (1219 mm) long minimum and shall extend from a point 2 inches (51 mm) maximum above the seat surface to a point 18 inches (457 mm) minimum above the seat...
-
612.2 Bench
Doors shall not swing into the clear floor space required by 903.2....
-
§ 38.93(b) Passageways
A route at least 32 inches wide shall be provided from doors required to be accessible by paragraph (a)(1) of this section to seating locations complying with §38.95(d) of this part....
-
DETECTABLE WARNING
A standardized surface feature built in or applied to walking surfaces or other elements to warn of hazards on a circulation path. Advisory Definition of DETECTABLE WARNING. ...
-
Water Play Components
If the surface of the accessible route, clear floor or ground spaces, and turning spaces that connect play components are submerged, the accessible route does not have to comply with the...
-
4.34.6.5(1)
(1) The sink and surrounding counter shall be mounted at a maximum height of 34 in (865 mm) above the floor, measured from the floor to the top of the counter surface, or shall be adjustable...
-
11B-705.3 Product Approval
Only approved DSA-AC detectable warning products and directional surfaces shall be installed as provided in the California Code of Regulations (CCR), Title 24, Part 1, Chapter 5, Articles...
-
11B-407.4.10 Support rail
Support rails in elevator cabs are used in a different way than handrails along a walking surface such as a ramp or stairway....
-
DETECTABLE WARNING
A standardized surface feature built in or applied to walking surfaces or other elements to warn persons with visual impairments of hazards on a circulation path....
-
1134A.2 Number of complying bathrooms
If a door is provided, it shall comply with the requirements of Section 1132A.5. 8. ...