Emergency shelters in older buildings with inaccessible features might be made accessible with temporary modifications, (such as portable ramps at the entrance and accessible parking spaces...
Search Results "Curb Ramp Surface"
-
H. After Completing the Survey and Checklist
-
IV. Summary of Comments and Responses on Other Aspects of the Proposed Rule
Access Board received about 100 written comments to the 2010 NPRM, including those received during the reopening of the comment period in the fall of 2012 to address issues related to ramp...
-
Historic Preservation [4.1.7]
These requirements address accessible routes, ramps, entrances, toilet rooms, access between floors, and displays....
-
1009.5.2 Transfer Space
A transfer space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
1005.2.1 Height
At least 25 percent of the railings, guards, or handrails shall be 34 inches (865 mm) maximum above the ground or deck surface....
-
403.5.1 Clear Width
Except as provided in 403.5.2 and 403.5.3, the clear width of walking surfaces shall be 36 inches (915 mm) minimum....
-
1005.2.1 Height
At least 25 percent of the railings, guards, or handrails shall be 34 inches (865 mm) maximum above the ground or deck surface....
-
1009.5.4 Transfer Steps
The surface of the bottom tread shall extend to a water depth of 18 inches (455 mm) minimum below the stationary water level. Advisory 1009.5.4 Transfer Steps....
-
R406.3 Unobstructed Side Reach
approach to an element and the side reach is unobstructed, the high side reach shall be 1220 mm (4.0 ft) maximum and the low side reach shall be 380 mm (1.25 ft) minimum above the finish surface...
-
4.1.7(3)(e)
., open books), should be no higher than 44 in (1120 mm) above the floor surface....
-
4.7.1 General
In alterations, where a condition for exception in section 1.1 prohibits full compliance with a specific requirement for clear floor or ground space surface, slope, size, or location, the...
-
Fixed tactile maps
Placement on a horizontal or near horizontal surface provides the map reader with a real world orientation....
-
6.9 Tread Obstacles
Where the surface is paved or is elevated above the natural ground, obstacles shall not exceed 1/2 inch (13 mm) in height measured vertically to the highest point....
-
11B-704.5 TTY shelf
The telephone handset shall be capable of being placed flush on the surface of the shelf....
-
Typical Transfer Techniques: Staff Assistance and Patient Lifts
Other individuals will need simple tools such as a transfer board (a product made of a smooth rigid material which acts as a supporting bridge between a wheelchair and another surface, along...
-
Transfer Supports (M301.3.1, M302.3.1, and M305.2)
M305.2.1 would require the transfer supports to be located within reach of the transfer surface and not obstruct transfer onto the surface when in position....
-
Clearance in Base (M301.4.1 and M302.4.1)
would require the clearance in the base to be 44 inches wide minimum, 6 inches high minimum measured from the floor, and 36 inches deep minimum measured from the edge of the examination surface...
-
Picnic Tables
All new picnic table installations must comply with requirements for accessible seating spaces, table clearance, slope, and surface....
-
GRADE (Adjacent Ground Elevation)
[DSA-AC & HCD 1-AC] The lowest point of elevation of the finished surface of the ground, paving or sidewalk within the area between the building and the property line or, when the property...
-
1011.2 Clear Ground Space
Where individual outdoor constructed features are altered and the ground surface is not altered, the clear ground space shall not be required to comply with 1011.2.2 and 1011.2.3. 2. ...
-
1005.2.1 Height
At least 25 percent of the railings, guards, or handrails shall be 34 inches (865 mm) maximum above the ground or deck surface....
-
Start of Play Areas
It must have a slope no steeper than 1:48 so that people using wheelchairs or mobility devices do not have to hit the ball while positioned on a sloped surface....
-
Accessible Routes
The accessible route must comply with ADAAG provisions for location, width (minimum of 36 inches), passing space, head room, surface, slope (maximum of 1:12 or 8.33%), changes in level,...
-
11B-1009.5.2 Transfer space
A transfer space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...