With respect to an alteration of a building or a facility, something that has little likelihood of being accomplished because existing structural conditions would require removing or altering...
Search Results "Supplemental Requirement"
Commonly Searched Documents
-
106.5.68 Technically Infeasible
-
4.13.12* Automatic Doors and Power-Assisted Doors
Such doors shall not open to back check faster than 3 seconds and shall require no more than 15 lbf (66.6N) to stop door movement....
-
Signage
Directional signage is required at inaccessible public entrances. Signage should be located to minimize backtracking....
-
Transit Facilities: Rail Stations
Transit Facilities: Rail Stations Much of the early research on detectable warnings was conducted at rapid rail stations and the requirement to provide a detectable warning remains in...
-
216.10 Assistive Listening Systems
Each assembly area required by 219 to provide assistive listening systems shall provide signs informing patrons of the availability of the assistive listening system....
-
Controls
Controls Push buttons or plates and switches are subject to relevant requirements for controls and operating mechanisms, including the maximum 5 Ib operating force....
-
Q7. What questions can a covered entity's employees ask to determine if a dog is a service animal?
In situations where it is not obvious that the dog is a service animal, staff may ask only two specific questions: (1) is the dog a service animal required because of a disability?...
-
4.1.7(1)(a) General Rule
specifications of 4.2 through 4.35 and the applicable special application sections 5 through 10 unless it is determined in accordance with the procedures in 4.1.7(2) that compliance with the requirements...
-
Width [4.3.3.] and Passing Space [4.3.4]
A continuous minimum clear width of 36 inches is required for accessible routes, but a reduction to 32 inches is allowed for a linear distance of no more than 24 inches (e.g., a doorway)...
-
404.1 General
This provision does not require the addition or translation of information, simply its preservation....
-
4.1.7(2)(a)(ii) ADA Application
If the State Historic Preservation Officer or Advisory Council on Historic Preservation agrees that compliance with the requirements for accessible routes (exterior and interior), ramps,...
-
Clear Floor Space [4.19.3]
Clear Floor Space [4.19.3] Clear floor space should be centered at the fixture (although this is not specifically required by ADAAG)....
-
Extensions
Extensions are not required in alterations if they project into cross circulation paths. Extensions must be rounded or returned to the walls, floors, or posts....
-
Controls [9.2.2(5)]
These requirements apply primarily to those controls and operating mechanisms intended for use by patrons; those used only by employees and facility operators for purposes of maintenance...
-
Chapter 10: Recreation Facilities
The final rule adds technical requirements to Chapter 10 for outdoor constructed features (1011); parking spaces within camping units and picnic units and pull-up spaces at dump stations...
-
1011.7 Outdoor Rinsing Showers
This section requires outdoor rinsing showers to provide at least one hand-held shower spray unit with a hose 59 inches long minimum....
-
4.2.4.1 SIZE AND APPROACH
The minimum clear floor or ground space required to accommodate a single, stationary wheelchair occupant is 30 in by 48 in (760 mm by 1220 mm) (see Fig. 4(a))....
-
4.1.6(1)(b)
., escalator) is planned or installed where none existed previously, or if new stairs (other than stairs installed to meet emergency exit requirements) requiring major structural changes...
-
3.4.3 Unrestricted Viewing Opportunities
Each viewing area that is required to be accessible by section 3.4.1 shall provide at least one unrestricted viewing opportunity that accommodates eye levels between 32 inches (815 mm) minimum...
-
F247.4.4 Routes
Routes that connect trails that do not comply with 1017 to camping facilities, picnic facilities, viewing areas, pit toilets, and accessible elements provided within the facilities are not required...
-
Knee Clearance: Clearance as Measured from Distal Knee Point - Manual Wheelchair
This depicts knee and toe clearance required by manual chair users for forward approach to elements in the built environment (e.g., lavatories, drinking fountains)....
-
3.4.1 General
When a new viewing area is constructed, or an existing viewing area is altered or reconstructed, if a condition for exception in section 1.1 prohibits full compliance with a specific requirement...
-
Knee Clearance: Clearance as Measured from Anterior-Most Abdomen Point - Manual Wheelchair
This depicts knee and toe clearance required by manual chair users for forward approach to elements in the built environment (e.g., dining tables)....
-
Floor and Ground Surfaces
This guide explains requirements in the ADA Standards for floor and ground surfaces. ...