compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1219 mm) maximum above the shower floor...
Search Results "Clear Floor Area"
Commonly Searched Documents
-
11B-608.5.1 Transfer type shower compartments
-
11B-604.9.5 Flush controls
Hand operated flush controls shall comply with Sections 11B-309.2 and 11B-309.4 and shall be installed 36 inches (914 mm) maximum above the finish floor....
-
11B-405.7.4 Change in direction
Ramps that change direction between runs at landings shall have a clear landing 60 inches (1525 mm) minimum by 72 inches (1829 mm) minimum in the direction of downward travel from the upper...
-
11B-405.7.4 Change in direction
Ramps that change direction between runs at landings shall have a clear landing 60 inches (1525 mm) minimum by 72 inches (1829 mm) minimum in the direction of downward travel from the upper...
- Disability and Employment Resources: SCVRD Part 1
-
11B-405.9.1 Reserved
[2010 ADAS] 405.9.1 Extended Floor or Ground Surface....
-
11B-217.4.2.2 Private buildings
Where four or more public pay telephones are provided on a floor of a private building, at least one public TTY shall be provided on that floor. ...
-
217.4.2.2 Private Buildings
Where four or more public pay telephones are provided on a floor of a private building, at least one public TTY shall be provided on that floor....
-
217.4.2.1 Public Buildings
Where at least one public pay telephone is provided on a floor of a public building, at least one public TTY shall be provided on that floor....
-
11B-217.4.2.1 Public buildings
Where at least one public pay telephone is provided on a floor of a public building, at least one public TTY shall be provided on that floor. ...
-
11B-217.4.2.2 Private buildings
Where four or more public pay telephones are provided on a floor of a private building, at least one public TTY shall be provided on that floor....
-
11B-217.4.2.1 Public buildings
Where at least one public pay telephone is provided on a floor of a public building, at least one public TTY shall be provided on that floor. ...
-
11B-217.4.2.1 Public buildings
Where at least one public pay telephone is provided on a floor of a public building, at least one public TTY shall be provided on that floor....
-
11B-217.4.2.2 Private buildings
Where four or more public pay telephones are provided on a floor of a private building, at least one public TTY shall be provided on that floor....
-
Armrests: ADA Standard Section 802.4.1
Where armrests are provided on the seating in the immediate area, folding or retractable armrests shall be provided on the aisle side of the seat....
-
11B-802.4.1 Armrests
Where armrests are provided on the seating in the immediate area, folding or retractable armrests shall be provided on the aisle side of the seat....
-
F - number system
F - number system The F - number system, ASTM E 1155, Standard Test Method for Determining FF Floor Flatness and FL Floor Levelness Numbers, was developed primarily to aid in the construction...
- AquaTrek2 ADA Step System
- Allegion Von Duprin 98/99 Series Exit Devices
-
11B-405.9.1 Reserved
[2010 ADAS] 405.9.1 Extended Floor or Ground Surface. ...
-
11B-405.9.1 Reserved.
[2010 ADA Standards] 405.9.1 Extended Floor or Ground Surface....
- Phonic Ear HearIt Media Wireless Amplifier for Televisions and Mobile Telephones
- Activar JL Industries Ambassador Series 1017F10 Steel Fire Extinguisher Cabinets
-
11B-604.7.2 Disposal units
The disposal unit shall be located below the grab bar with the opening of the disposal unit 19 inches minimum (483 mm) above the finish floor....