The running slope of ramps and bridgeplates used for deployment to the roadway or to curb-height boarding and alighting areas shall be 1:6 maximum, as measured to ground level with the non-rail...
Search Results "Floor-Level Exit Sign"
Commonly Searched Documents
-
T402.8.1 Deployment to Roadways or to Curb Height Boarding and Alighting Areas
-
11B-1002.4.4.3 Permitted protrusions in wheelchair spaces
permitted to protrude a distance of 6 inches (152 mm) maximum along the front of the wheelchair space, where located 9 inches (229 mm) minimum and 27 inches (686 mm) maximum above the floor...
-
1002.4.4.3 Permitted Protrusions in Wheelchair Spaces
permitted to protrude a distance of 6 inches (150 mm) maximum along the front of the wheelchair space, where located 9 inches (230 mm) minimum and 27 inches (685 mm) maximum above the floor...
-
407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with tactile symbols as shown in Table 407.4.7.1.3....
-
609.4 Position of Grab Bars
Grab bars shall be installed in a horizontal position, 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
7b.
[ADA Stds 4.13.9] Yes _____ No _____ A clear floor space on the latch side of the door (pull side) allows a person using a wheelchair or scooter to pull the door open and then...
-
4.1.3(10)(a)
(a) Where only one drinking fountain is provided on a floor there shall be a drinking fountain which is accessible to individuals who use wheelchairs in accordance with 4.15 and one accessible...
-
609.4 Position of Grab Bars
Grab bars shall be installed in a horizontal position, 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
11B-405.9.2 Curb or barrier
mm) high minimum, or barrier shall be provided that prevents the passage of a 4 inch (102 mm) diameter sphere, where any portion of the sphere is within 4 inches (102 mm) of the finish floor...
-
§ 38.23(b)(7) Platform gaps
When the platform is at vehicle floor height with the inner barrier (if applicable) down or retracted, gaps between the forward lift platform edge and the vehicle floor shall not exceed...
-
11B-405.9.2 Curb or barrier
A curb or barrier shall be provided that prevents the passage of a 4-inch (102 mm) diameter sphere, where any portion of the sphere is within 4 inches (102 mm) of the finish floor or ground...
-
Talking Three-Dimensional Models for Way-finding
and details that are irrelevant to a tactile reader who is planning a walking route, because they don’t need to know, for example, how tall a building is in order to walk there at ground level...
-
11B-202.4 Path of travel requirements in alterations, additions and structural repairs
Signs....
-
11B-202.4 Path of travel requirements in alterations, additions and structural repairs
accessible level....
-
[A] ADDITION
[DSA-AC] An expansion, extension, or increase in the gross floor area or height of a building or facility....
-
11B-411.4.8.2.1 Signal type
The signal shall be an automatic verbal annunciator which announces the floor at which the car is about to stop....
-
602.4 Spout Height
Spout outlets shall be 36 inches (915 mm) maximum above the finish floor or ground....
-
602.4 Spout Height
Spout outlets shall be 36 inches (915 mm) maximum above the finish floor or ground....
-
11B-602.4 Spout height
Spout outlets shall be 36 inches (914 mm) maximum above the finish floor or ground....
-
4.24.2 HEIGHT
Sinks shall be mounted with the counter or rim no higher than 34 in (865 mm) from the floor....
-
11B-411.4.8.2.1 Signal type
The signal shall be an automatic verbal annunciator which announces the floor at which the car is about to stop....
-
11B-411.4.8.2.1 Signal type
The signal shall be an automatic verbal annunciator which announces the floor at which the car is about to stop....
-
11B-602.4 Spout height
Spout outlets shall be 36 inches (914 mm) maximum above the finish floor or ground....
-
11B-813.2.1 Adult changing table
Adult changing tables shall be fixed to the floor or a wall and shall comply with Section 11B-813.2.1....