Hand operated flush controls shall comply with Section 11B-309 except that the flush control shall be mounted at a maximum height of 44 inches (1118 mm) above the finish floor....
Search Results "Ground Floor Exit"
-
11B-605.4 Flush controls
-
11B-809.10.8.1 Location
The top of the lavatory rim shall be 34 inches (864 mm) maximum above the finished floor....
-
810 Transportation Facilities
This revision does not substantively change the requirements for the coordination of platforms and vehicle floors. Comment....
-
903.3.1.1.1 Exempt locations
Generator and transformer rooms separated from the remainder of the building by walls and floor/ceiling or roof/ceiling assemblies having a fire-resistance rating of not less than 2 hours...
-
11B-604.6 Flush controls
Hand operated flush controls shall comply with Section 11B-309 except they shall be located 44 inches (1118 mm) maximum above the floor....
-
11B-604.6 Flush controls
Hand operated flush controls shall comply with Section 11B-309 except they shall be located 44 inches (1118 mm) maximum above the floor....
- Whitehall Mfg. WH3740 Ligature Resistant Stainless Steel Basin
-
Sales and Service Counters
At counters having a cash register, a section of counter at least 36 inches long and not more than 36 inches above the floor will make the counter accessible....
-
M301.2.1, M302.2.1 Transfer Height
Transfer Height Proposed requirement: The height of the transfer surface during patient transfer shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum measured from the floor...
- Landscape Forms Inc. Multiplicity Bench Collection
- Landscape Forms Inc. Strata Beam Bench Collection
-
Accessible Courtroom Stations
Clear floor space for a forward approach is required for all courtroom stations (judges’ benches, clerks’ stations, bailiffs’ stations, deputy clerks’ stations, court reporters’ stations...
-
607 Bathtubs
Specifications for bathtubs in section 607 address clear floor space, seats, grab bars, operable parts, shower spray units, and enclosures....
-
Exercise machines. (Section-by-Section Analysis)
Sections 206.2.13 and 236 of the 2004 ADAAG require one of each type of fixed exercise machine to meet clear floor space specifications and to be on an accessible route. ...
-
Exercise machines. (Section-by-Section Analysis)
Sections 236 and 206.2.13 of the 2004 ADAAG require one of each type of fixed exercise machine to meet clear floor space specifications and to be on an accessible route....
-
A. Accessible Counters
.: where no direct service is provided) accessible, providing a 27" high knee space, at least 19" deep, with table/counter tops at 28"-34" above the floor and split proportionately between...
-
4.34.5.5(2) Seat
The seat shall be 17 in to 19 in (430 mm to 485 mm) high measured from the bathroom floor and shall extend the full depth of the stall....
-
11B-605.4 Flush controls
Hand operated flush controls shall comply with Section 11B-309 except that the flush control shall be mounted at a maximum height of 44 inches (1118 mm) above the finish floor....
-
1132A.4, Item 3
Changes in height greater than ½ inch (12.7 mm) shall be accomplished by means of a ramp complying with Section 1114A or by means of a platform constructed to the level of the floor as illustrated...
-
I. INTRODUCTION
Amicus curiae United States of America urges the Court to reject these Agreements on numerous grounds....
- Wingits Reversible L-shaped 26" x 22.5" Shower Seat
- Cybex Total Access Upright Bike
-
Text Telephones (TTY)
Section 217.4.2 of the 2010 Standards requires that a building or facility provide a public TTY on each floor that has four or more public telephones, and in each telephone bank that has...
-
RECOMMENDED CHANGE
medical devices, requires a similar instability test in section 9.4.2.3: ME EQUIPMENT having a mass of 25 kg or more, other than FIXED ME EQUIPMENT that is intended to be used on the floor...