In transfer type compartments, grab bars shall be provided across the control wall and back wall to a point 18 inches (457 mm) from the control wall....
Search Results "Transfer Space"
Commonly Searched Documents
- 
    
  
  11B-608.3.1 Transfer type shower compartments
  
 - AquaTrek2 ADA Transfer System
 - Acoustical Society of America - American National Standard Acoustical Performance Criteria, Design Requirements, and Guidelines for Schools, Part 2: Relocatable Classroom Factors
 - 
    
  
  Forward Approach: ADA Standard Section 305.7.1
  
Section 305.7.1 covers the current ADA Standards for the clear floor or ground space required for forward approach.
 - 
    
  
  Parallel Approach: ADA Standard Section 305.7.2
  
Section 305.7.2 covers the current ADA Standards for the clear floor or ground space required for parallel approach.
 - 
    
  
  Chapter 4: Implications for standards and design
  
[See subsections ...]
 - 
    
  
  Transfer Surface (M301.2 and M302.2)
  
The technical criteria in M301.2 and M302.2 address the height and size of the transfer surface, and the transfer sides....
 - 
    
  
  Analysis of Transfer Surface Dimensions Based on Wheeled Mobility User Anthropometry
  
Access Board RE: Analysis of Transfer Surface Dimensions Based on Wheeled Mobility User Anthropometry...
 - 
    
  
  Passing Spaces: ADA Standard Section 403.5.3
  
Section 403.5.3 covers the current ADA Standards for passing spaces that are part of an accessible route.
 - 
    
  
  Addendum F: Relative Height Differences
  
Relative Height Difference for High and Low Transfers for Protocol A. ...
 - 
    
  
  5.2.2.2 Transfer Surface Depth
  
5.2.2.2 Transfer Surface Depth. The transfer surface should be 17 inches deep minimum for equipment used by patients in a seated position....
 - 
    
  
  Clear Floor or Ground Space: ADA Standard Section 902.2
  
A clear floor space complying with 305 positioned for a forward approach shall be provided. Knee and toe clearance complying with 306 shall be provided....
 - 
    
  
  5.2.2.1 Transfer Surface Width
  
5.2.2.1 Transfer Surface Width. The transfer surface should be 21 inches wide minimum for examination chairs and other equipment used by patients in a seated position....
 - 
    
  
  1009.1 General
  
Where provided, pool lifts, sloped entries, transfer walls, transfer systems, and pool stairs shall comply with 1009....
 - 
    
  
  1009.1 General
  
Where provided, pool lifts, sloped entries, transfer walls, transfer systems, and pool stairs shall comply with 1009....
 - 
    
  
  11B-1009.1 General
  
Where provided, pool lifts, sloped entries, transfer walls, transfer systems, and pool stairs shall comply with Section 11B-1009....
 - 
    
  
  1009.1 General
  
Where provided, pool lifts, sloped entries, transfer walls, transfer systems, and pool stairs shall comply with 1009....
 - 
    
  
  11B-1009.1 General
  
Where provided, pool lifts, sloped entries, transfer walls, transfer systems, and pool stairs shall comply with Section 11B-1009....
 - 
    
  
  11B-1009.1 General
  
Where provided, pool lifts, sloped entries, transfer walls, transfer systems, and pool stairs shall comply with Section 11B-1009....
 - 
    
  
  Size: ADA Standard Section 304.3
  
Section 304.3 covers the current ADA Standards for the required size of turning space.
 - 
    
  
  11B-903.2 Clear floor or ground space
  
Clear floor or ground space complying with Section 11B-305 shall be provided and shall be positioned at the end of the bench seat and parallel to the short axis of the bench....
 - 
    
  
  Incidental Spaces: ADA Standard Section 206.7.3
  
Section 206.7.3 covers scoping requirements in the most current ADA Standards for accessible routes to incidental spaces.
 - PlayLSI: A Higher Level of Inclusive Play
 - 
    
  
  5.4.4.2 Transfer Support Distance from Transfer Surface Recommendation for Imaging Equipment
  
5.4.4.2 Transfer Support Distance from Transfer Surface Recommendation for Imaging Equipment The Committee recommends a maximum distance of 1 1/2 inches from the transfer surface to the...