However, for the setup of the baseline level transfer (when the person and mobility device were in a position next to platform ready to transfer), if there was a noticeable difference (one...
Search Results "Transfer Space"
-
Initial Measures and Transfer Setup
-
M302.2 Transfer Surface
M302.2 Transfer Surface M302.2.3 Transfer Sides Proposed requirement: The transfer surface shall be located to provide options to transfer from a mobility device onto one short...
-
1014.2.1.1.2 Slope
The slope of the surface of the clear ground space shall not be steeper than 1:48 in any direction....
-
1014.2.1.1.2 Slope
The slope of the surface of the clear ground space shall not be steeper than 1:48 in any direction....
-
11B-203.4 Limited access spaces
Spaces not customarily occupied and accessed only by ladders, catwalks, crawl spaces, or very narrow passageways shall not be required to comply with these requirements or to be on an accessible...
-
11B-203.4 Limited access spaces
Spaces not customarily occupied and accessed only by ladders, catwalks, crawl spaces, or very narrow passageways shall not be required to comply with these requirements or to be on an accessible...
-
11B-1008.2.4.2 Elevated
The clear width of transfer systems connecting elevated play components shall be permitted to be 24 inches (610 mm) minimum....
-
11B-1008.2.4.2 Elevated
The clear width of transfer systems connecting elevated play components shall be permitted to be 24 inches (610 mm) minimum....
-
11B-234.3 Minimum number
Amusement rides shall provide at least one wheelchair space complying with Section 11B-1002.4, or at least one amusement ride seat designed for transfer complying with Section 11B-1002.5...
-
11B-234.3 Minimum number
Amusement rides shall provide at least one wheelchair space complying with Section 11B-1002.4, or at least one amusement ride seat designed for transfer complying with Section 11B-1002.5...
-
11B-234.3 Minimum number
Amusement rides shall provide at least one wheelchair space complying with Section 11B-1002.4, or at least one amusement ride seat designed for transfer complying with Section 11B-1002.5...
-
Chapter 1: Background
space (length/width) needed to position the wheelchair in proximity to the target....
-
Dome Spacing: ADA Standard Section 705.1.2
Truncated domes in a detectable warning surface shall have a center-to-center spacing of 1.6 inches (41 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch...
-
11B-811.2 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided....
-
11B-811.2 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided....
-
Elevated: ADA Standard Section 1008.2.4.2
The clear width of transfer systems connecting elevated play components shall be permitted to be 24 inches (610 mm) minimum....
-
Wheelchair Operation (Helping #6)
Requires the Registered User plan or above. Login!
-
CLEAR FLOOR SPACE
[DSA-AC] The minimum unobstructed floor or ground space required to accommodate a single, stationary wheelchair and occupant....
-
CLEAR FLOOR SPACE
[DSA-AC] The minimum unobstructed floor or ground space required to accommodate a single, stationary wheelchair and occupant....
-
5.3.2.1 Transfer Sides Recommendation for Stretchers
5.3.2.1 Transfer Sides Recommendation for Stretchers On stretchers, the transfer surface is oriented along the long dimension of the surface on which patients are in the supine, prone...
-
J. Transfer Space
If there is a lavatory in the accessible stall, is there 42" between the center of the toilet and the near edge of the adjacent lavatory to permit persons with disabilities to transfer onto...
-
(3) Adjustability: Transfer Surface Intermediate Heights
In the MDE NPRM there was no requirement for the transfer surface to have intermediate transfer heights....
-
608.3.1 Transfer Type Shower Compartments
608.3.1 Transfer Type Shower Compartments....
-
Clear Floor or Ground Space: ADA Standard Section 805.3
A clear floor space complying with 305 shall be provided on each side of the bed. The clear floor space shall be positioned for parallel approach to the side of the bed....