Section 216.4.3 covers scoping requirements in the current ADA Standards for directional signs.
Search Results "Signage Height"
Commonly Searched Documents
-
Directional Signs: ADA Standard Section 216.4.3
-
5.1.5 Floor Height
Where the floor at the entrance to the camp shelter is elevated above the ground surface, the floor shall be 17 (430 mm) high minimum to 19 inches (485 mm) high maximum measured from...
-
4.19.2 Height and Clearances
Lavatories shall be mounted with the rim or counter surface no higher than 34 in (865 mm) above the finish floor. Provide a clearance of at least 29 in (735 mm) above the finish...
-
4.19.2 HEIGHT AND CLEARANCES
Lavatories shall be mounted with the rim or counter surface no higher than 34 in (865 mm) above the finished floor. Provide a clearance of at least 29 in (735 mm) from the floor to...
-
602.4 Spout Height
602.4 Spout Height. Spout outlets shall be 36 inches (915 mm) maximum above the finish floor or ground....
-
1009.9 Signage
Signage indicating special accessibility provisions shall be provided as shown: 1....
-
Signage
Comment and Question by Tom Williams: Along with the discussion about wayfinding and signage, it brings out the issue of contrast and tactile signs and so on....
-
11B-902.4.2 Height
The tops of tables and counters shall be 26 inches (660 mm) minimum and 30 inches (762 mm) maximum above the finish floor or ground.
-
11B-902.4.2 Height
The tops of tables and counters shall be 26 inches (660 mm) minimum and 30 inches (762 mm) maximum above the finish floor or ground.
-
11B-902.4.2 Height
The tops of tables and counters shall be 26 inches (660 mm) minimum and 30 inches (762 mm) maximum above the finish floor or ground.
-
505.4 Height
505.4 Height....
- Access Board: Directional Signage at Inaccessible Entrances
-
1008.1.9.7, Item 5
THIS DOOR WILL OPEN IN 15 [30] SECONDS ALARM WILL SOUND” Sign lettering shall be at least 1 inch (25 mm) in height and shall have a stroke of not less than 1/8 inch (3.2 mm)....
- 605.2 Urinal Height to Rim
-
505.4 Height
Handrails shall be at a consistent height above walking surfaces, stair nosings, and ramp surfaces. Advisory 505.4 Height....
-
505.4 Height
Handrails shall be at a consistent height above walking surfaces, stair nosings, and ramp surfaces. [ECTCR UFAS 4.8.5(5), 4.9.4(5)] Advisory 505.4 Height....
-
4.1.6(1)(h) Entrances
If a particular entrance is not made accessible, appropriate accessible signage indicating the location of the nearest accessible entrance(s) shall be installed at or near the inaccessible...
- SafetySign Van Accessible Parking Signage (Green Text and Border)
-
Finish and Contrast [4.30.5]
Finish and Contrast [4.30.5] All signs covered by 4.30 must have a non-glare finish, such as matte or eggshell. Recommendations: An eggshell finish is recommended. Consideration...
-
703.5.6 Height From Finish Floor or Ground
Visual characters shall be 40 inches (1015 mm) minimum above the finish floor or ground. EXCEPTION: Visual characters indicating elevator car controls shall not be required to...
-
7. Lavatory
7. Is the lavatory (wash basin) in each accessible guestroom bathroom no more than 34" high with at least 29" high clearance under the front edge to allow persons who use wheelchairs...
-
Circulation and flow
There is no signage to the interior accessible route between the Museum lobby and the Spy City Café. See Standards § 4.1.2(7)(c). b....
-
11B-1009.2.4 Seat
The height of the lift seat shall be designed to allow a stop at 17 inches (432 mm) minimum to 19 inches (483 mm) maximum measured from the deck to the top of the seat surface when in the...
-
Permanent Rooms and Spaces
Section 216.2 covers designations of permanent rooms and spaces, including pictograms provided as part of such signs. These types of signs are required to be tactile through the...