Required guards shall not be less than 42 inches (1067 mm) high, measured vertically as follows: From the adjacent walking surfaces. On stairways and stepped aisles, from the...
Search Results "Means of Entry"
Commonly Searched Documents
- 
    
  
  1015.3 Height
  
- 
    
  
  1011.5.2 Riser height and tread depth
  ... Exceptions: 4. See California Fire Code Chapter 11 and California Existing Building Code for the replacement of existing stairways. [DSA-AC] For applications listed in... 
- 
    
  
  1009.8.2 Directions
  Directions for the use of the two-way communication system, instructions for summoning assistance via the two-way communication system and written identification of the location... 
- 
    
  
  1010.1.8 Door arrangement
  Space between two doors in a series shall be 48 inches (1219 mm) minimum plus the width of a door swinging into the space. Doors in a series shall swing either in the same direction... 
- 
    
  
  1018.3 Aisles in Groups B and M
  In Group B and M occupancies, the minimum clear aisle width shall be determined by Section 1005.1 for the occupant load served, but shall be not less than that required for corridors... 
- 
    
  
  1018.5 Aisles in other than assembly spaces and Groups B and M
  In other than rooms or spaces used for assembly purposes and Group B and M occupancies, the minimum clear aisle capacity shall be determined by Section 1005.1 for the occupant load... 
- 
    
  
  1007.6.4  Instructions
  The instructions shall include all of the following: Directions to find other means of egress.... 
- 
    
  
  1003.2.13.5.4 Instructions
  Directions to find other means of egress. 2. Persons able to use the exit stairway do so as soon as possible, unless they are assisting others. 3.... 
- 
    
  
  11B-207.1 General
  Means of egress shall comply with Chapter 10, Section 1007. [2010 ADAS] 207.1 General.... 
- 
    
  
  11B-207.1 General
  Means of egress shall comply with Chapter 10, Section 1009. [2010 ADAS] 207.1 General.... 
- 
    
  
  11B-207.1 General
  Means of egress shall comply with Chapter 10, Section 1009. [2010 ADA Standards] 207.1 General.... 
- 
    
  
  1009.12 Alarms/emergency warning systems/accessibility
  If emergency warning systems are required, they shall activate a means of warning the hearing impaired.... 
- 
    
  
  1009.12 Alarms/emergency warning systems/accessibility
  If emergency warning systems are required, they shall activate a means of warning the hearing impaired.... 
- 
    
  
  Wedges
  [See subsections ...] 
- 
    
  
  Section H: Lifts
  Ward:__________ Precinct:__________ Staff:_______________ Date:_________ Time:_________ Address:_______________________________________ Location... 
- 
    
  
  1007.12 Alarms/emergency warning systems/accessibility
  If emergency warning systems are required, they shall activate a means of warning the hearing impaired.... 
- SafePath: Threshold Ramp Installation for MultiFamily Housing for Disability Access
- 
    
  
  EZ-ACCESS® Incline Calculator for Ramp Solutions
  EZ-ACCESS® Incline Calculator [Click here to access the online calculator] To Establish the Proper Ramp Length: Determine the incline that your chair is designed to... 
- 
    
  
  Required Compliance [§210]
  Required Compliance [§210] Interior and exterior stairs that are part of a required means of egress must meet the Standards.... 
- 
    
  
  11B-210.1 General
  Interior and exterior stairs that are part of a means of egress shall comply with 504. Exceptions: 1.... 
- 
    
  
  1007.6.1 Size
  Such wheelchair spaces shall not reduce the required means of egress width.... 
- 
    
  
  1009.6.3 Size
  Such wheelchair spaces shall not reduce the means of egress minimum width or required capacity.... 
- 
    
  
  1009.6.3 Size
  Such wheelchair spaces shall not reduce the means of egress minimum width or required capacity.... 
- 
    
  
  General: ADA Standard Section 210.1
  Section 210.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for stairways. 