The disposal unit shall be located below the grab bar with the opening of the disposal unit 19 inches minimum (483 mm) above the finish floor....
Search Results "Finished Grade"
Commonly Searched Documents
-
11B-604.7.2 Disposal units
-
11B-407.2.1.1 Height
[2010 ADA Standards] EXCEPTION: Existing call buttons and existing keypads shall be permitted to be located at 54 inches (1370 mm) maximum above the finish floor, measured to the centerline...
-
11B-803.6 Mirrors
Mirrors shall be installed with the bottom edge of the reflecting surface 20 inches (508 mm) maximum above the finish floor or ground....
-
11B-306.3.4 Clearance reduction
Between 9 inches (229 mm) and 27 inches (686 mm) above the finish floor or ground, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for each 6 inches...
-
Garage Parking
The Standards apply to parking garages, including those provided below grade....
-
30.1 Q. Would it be acceptable to use removable base cabinets beneath a wall-hung lavatory where a parallel approach is not possible?
The space under and around the cabinet should be finished prior to installation. For example, the tile or other floor finish must extend under the removable base cabinet....
-
5.1 Q...Would the first story of single-story dwelling units over the parking level be required to be accessible?
definition of ground floor found in HUD's regulation implementing the Fair Housing Act (see 24 CFR 100.201) to indicate that . . .where the first floor containing dwelling units is above grade...
-
11B-306.3.3 Minimum required depth
Where knee clearance is required under an element as part of a clear floor space, the knee clearance shall be 11 inches (279 mm) deep minimum at 9 inches (229 mm) above the finish floor...
-
11B-306.3.3 Minimum required depth
Where knee clearance is required under an element as part of a clear floor space, the knee clearance shall be 11 inches (279 mm) deep minimum at 9 inches (229 mm) above the finish floor...
-
11B-306.3.3 Minimum required depth
Where knee clearance is required under an element as part of a clear floor space, the knee clearance shall be 11 inches (279 mm) deep minimum at 9 inches (229 mm) above the finish floor...
-
BLENDED TRANSITION
[DSA-AC] A raised pedestrian crossing, depressed corner or similar connection that has a grade of 5 percent or less a circulation path at the level of the sidewalk or walk and the level...
-
R405.2.1 General
Space under an element between the finish surface and 230 mm (9 in) above the finish surface shall be considered toe clearance and shall comply with R405.2....
-
306.2.1 General
Space under an element between the finish floor or ground and 9 inches (230 mm) above the finish floor or ground shall be considered toe clearance and shall comply with 306.2....
-
306.2.1 General
Space under an element between the finish floor or ground and 9 inches (230 mm) above the finish floor or ground shall be considered toe clearance and shall comply with 306.2....
-
306.2.1 General
Space under an element between the finish floor or ground and 9 inches (230 mm) above the finish floor or ground shall be considered toe clearance and shall comply with 306.2....
-
306.2.1 General
Space under an element between the finish floor or ground and 9 inches (230 mm) above the finish floor or ground shall be considered toe clearance and shall comply with 306.2....
-
Refrigerator/Freezer: ADA Standard Section 804.6.6
Combination refrigerators and freezers shall have at least 50 percent of the freezer space 54 inches (1370 mm) maximum above the finish floor or ground....
-
11B-804.6.6 Refrigerator/freezer
Combination refrigerators and freezers shall have at least 50 percent of the freezer space 54 inches (1372 mm) maximum above the finish floor or ground....
-
R404.2 Surfaces
Surfaces of clear spaces shall comply with R302.7 and shall have a running slope consistent with the grade of the adjacent pedestrian access route and cross slope of 2 percent maximum....
-
Technical requirements
Technical requirements state the specific numbers, conditions, and measurements that are required (percent that must comply, dimensions, reach ranges, grades, trail width, and so forth)....
-
1(2)(a)(ii) Site analysis test
an accessible entrance served by an accessible route can be established by the following steps: (A) The percentage of the total buildable area of the undisturbed site with a natural grade...
-
1013.4 Raised character and braille exit signs
Each grade-level exterior exit door that is required to comply with Section 1013.1 shall be identified by a tactile exit sign with the word, “EXIT.” 2....
-
11B-404.2.7 Door and gate hardware
Operable parts of such hardware shall be 34 inches (864 mm) minimum and 44 inches (1118 mm) maximum above the finish floor or ground....
-
11B-306.2.1 General
Space under an element between the finish floor or ground and 9 inches (229 mm) above the finish floor or ground shall be considered toe clearance and shall comply with Section 11B-306.2...