Where a clear floor or ground space is located in an alcove or otherwise confined on all or part of three sides, additional maneuvering clearance shall be provided in accordance with 305.7.1...
Search Results "Side Transfer Surface"
-
305.7 Maneuvering Clearance
-
4.30.6 MOUNTING LOCATION AND HEIGHT
Interior signage shall be located alongside the door on the latch side and shall be mounted at a height of between 54 in and 66 in (1370 mm and 1675 mm) above the finished floor....
-
4.34.5.2(1)
The water closet may be located with the clear area at either the right or left side of the toilet....
-
305.7 Maneuvering Clearance
Where a clear floor or ground space is located in an alcove or otherwise confined on all or part of three sides, additional maneuvering clearance shall be provided in accordance with 305.7.1...
-
11B-213.3.6 Bathing facilities
Transfer type shower compartments shall be permitted in transient lodging guest rooms, multi-bedroom housing units in undergraduate student housing and residential dwelling units; and shall...
-
11B-213.3.6 Bathing facilities
Transfer type shower compartments shall be permitted in transient lodging guest rooms, multi-bedroom housing units in undergraduate student housing and residential dwelling units; and shall...
-
1117B.5.7
Where permanent identification signs are provided for rooms and spaces, signs shall be installed on the wall adjacent to the latch side of the door....
-
11B-704.5 TTY shelf
The telephone handset shall be capable of being placed flush on the surface of the shelf....
-
11B-407.4.6.2.1 Size and shape
Buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in their smallest dimension and be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding surface...
-
TTY Shelf: ADA Standard Section 704.5
The telephone handset shall be capable of being placed flush on the surface of the shelf....
-
11B-407.4.6.2.1 Size and shape
Buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in their smallest dimension and be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding surface...
-
11B-704.5 TTY shelf
The telephone handset shall be capable of being placed flush on the surface of the shelf....
-
705.1.3 Contrast
Detectable warning surfaces shall contrast visually with adjacent walking surfaces either light-on-dark, or dark-on-light. Figure 705.1 Size and Spacing of Truncated Domes...
-
407.3.1 Identification (Section-by-Section Analysis)
It also would require key surfaces outside active areas of display screens to be raised above their surrounding surfaces....
-
Purpose
Purpose For many years, the National Center on Accessibility (NCA) at Indiana University received questions from organizations, agencies and individuals on how to make natural surface...
-
407.3.1 Identification
Where provided, key surfaces outside active areas of the display screen shall be raised above surrounding surfaces....
-
1133A.3 Removable base cabinets
Sinks and work surfaces required by Section 1133A.4 (see Item 1 and Item 2) shall be provided with knee and toe space complying with Section 1133A.7....
-
1133A.3 Removable base cabinets
Sinks and work surfaces required by Section 1133A.4 (see Item 1 and Item 2) shall be provided with knee and toe space complying with Section 1133A.7....
-
409.4.6.2 Location
Control panels shall be on a side wall, 12 inches (305 mm) minimum from any adjacent wall. Figure 409.4.6.2 Location of Private Residence Elevator Control Panel...
-
T215.2.4 Destination and Route Signs
Where destination or route signs are provided on the exterior of non-rail vehicles, such signs shall be located at a minimum on the front and boarding sides of the vehicle....
-
H23
Is the door to the toilet stall located diagonally opposite, not directly in front of, the toilet or on the opposite side wall from the wall with the long grab bar?...
-
4.7.9 Location at Marked Crossings
Curb ramps at marked crossings shall be wholly contained within the markings, excluding any flared sides (see Fig. 15). ...
-
4.7.9 LOCATION AT MARKED CROSSINGS
Curb ramps at marked crossings shall be wholly contained within the markings, excluding any flared sides (see Fig. 15). Figure 15 Curb Ramps at Marked Crossings...
-
§ 38.159(c)(4) Ramp barriers
Each side of the ramp shall have barriers at least 2 inches (50 mm) high to prevent mobility aid wheels from slipping off....