Accella Adjustable Activity/Computer Table Attractive and modern, this height-adjustable table is ideal as a wheelchair accessible activity table or computer workstation....
Search Results "Treatment Table"
- Populas Accella Adjustable Activity / Computer Workstation
-
604.8.1.1 Size
This space cannot be obstructed by baby changing tables or other fixtures or conveniences, except as specified at 604.3.2 (Overlap)....
-
M301.4.2 Clearance Around Base
The base of diagnostic equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of the...
-
M301.4.1 Clearance in Base
The base of diagnostic equipment shall provide a clearance 39 inches (990 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep...
-
M305.5 Head and Back Support (Section-by-Section Analysis)
One manufacturer asserted that this requirement was ambiguous and that he had to read it multiple times to understand it; however, this commenter also indicated that the tables it currently...
-
604.8.1.1 Size
This space cannot be obstructed by baby changing tables or other fixtures or conveniences, except as specified at 604.3.2 (Overlap)....
-
604.8.1.1 Size
This space cannot be obstructed by baby changing tables or other fixtures or conveniences, except as specified at 604.3.2 (Overlap)....
-
How to Measure Transfer Surface Height
Many medical examination rooms are equipped with fixed height examination tables, with a typical 32-inch seat height....
-
11B-249.1.2
Newly constructed commercial places of public amusement shall provide no fewer than one adult changing facility in compliance with Section 11B-813. ETA Editor's Note The...
-
5.2 Transfer Surface Size for Equipment Used by Patients in Supine, Prone, or Side-Lying Position
5.2 Transfer Surface Size for Equipment Used by Patients in Supine, Prone, or Side-Lying Position.
-
5.2.1 Transfer Surface Size
5.2.1 Transfer Surface Size
-
M301.2 Transfer Surface
A transfer surface shall be provided and shall comply with M301.2.
-
36 CFR Part 1195 Proposed Accessibility Standards for Medical Diagnostic Equipment - Example Applications of Proposed Standards
Example Applications of the Proposed Medical Diagnostic Equipment Accessibility Standards January 23, 2012
-
11B-604.8.1.1 Size
When deployed the baby changing tables shall not obstruct the required width of the accessible route except as allowed by Section 11B-307.2....
-
M301.2 Transfer Surface
A transfer surface shall be provided and shall comply with M301.2.
-
M301.2.2 Size
The transfer surface shall be 30 inches (760 mm) wide minimum and 15 inches (381mm) deep minimum. Advisory M301.2.2 Size. The size requirements in this section apply only to the...
- Mockett TLKNB27 Original Kyros Leg 5" Base
-
Associated Constructed Feature
Examples include overnight shelters, toilets, fire rings, picnic tables, and tent pads. Refer to the FSORAG for the technical provisions for associated constructed features....
-
11B-604.8.1.1 Size
This space cannot be obstructed by baby changing tables or other fixtures or conveniences, except as specified at 604.3.2 (Overlap)....
-
M305.4 Leg Supports (Section-by-Section Analysis)
As discussed above in Section V.C.3.b (Section-by-Section Analysis – M301.3.2) and Section V.C.7.b (Section-by-Section Analysis – M302.3.2), the technical requirements for leg...
-
Associated Constructed Feature
Examples include camp shelters, pit toilets, fire rings, picnic tables, and tent pads. Refer to FSORAG for the technical provisions for associated constructed features....
-
M305.4 Leg Supports
Leg supports shall provide a method of supporting, positioning, and securing the patient’s legs.
- 309.3 Baby Changing Table Pull Down Handle Height
-
M301.2.3 Size (Section-by-Section Analysis)
The MDE NPRM proposed a transfer surface size for diagnostic equipment used in the supine, prone, or side-lying position of 30 inches wide and 15 inches deep minimum. (proposed...