If the height of the vehicle floor from which the ramp is deployed is 3 inches or less above a 6-inch curb, a maximum slope of 1:4 is permitted; if the height of the vehicle floor from which...
Search Results "Permit"
-
§ 38.23(c)(5) Slope
-
Temporary and Permanent Structures: ADA Standard Section 201.3
Section 201.3 covers the application of the most current requirements for temporary and permanent structures.
-
Identification: ADA Standard Section 809.5.5.2
Such peepholes can be placed at a standard height and permit a view from several feet from the door....
-
Vehicle Spaces: ADA Standard Section 502.2
Section 502.2 covers the current ADA Standards for vehicle spaces.
-
Power Operation: ADA Standard Section 409.3.1
Section 409.3.1 covers the current ADA Standards for the power operation of private residence elevator doors.
-
Seats: ADA Standard Section 608.4
Section 608.4 covers the current ADA Standards for seats in shower compartments.
-
Handrails: ADA Standard Section 405.8
Section 405.8 covers the current ADA Standards for ramp handrails.
-
Clear Floor Space: ADA Standard Section 602.2
Section 602.2 covers the current ADA Standards for drinking fountain clear floor space.
-
11B-812.1 General
Exception: Where vehicle spaces or access aisles are not adjacent to another vehicle space, access aisle, or parking space, measurements shall be permitted to include the full width of the...
-
11B-808.3 Clear floor space
Exception: In alterations, wheelchair spaces are not required to be located within the defined area of raised jury boxes or witness stands and shall be permitted to be located outside these...
-
11B-812.1 General
Exception: Where vehicle spaces or access aisles are not adjacent to another vehicle space, access aisle, or parking space, measurements shall be permitted to include the full width of the...
-
11B-808.3 Clear floor space
Exception: In alterations, wheelchair spaces are not required to be located within the defined area of raised jury boxes or witness stands and shall be permitted to be located outside these...
-
11B-404.2.4.4 Floor or ground surface
Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted. Exceptions: Reserved....
-
Door and Gate Hardware: ADA Standard Section 404.2.7
Section 404.2.7 covers the current ADA Standards for door and gate hardware.
-
1010.1.6 Thresholds
In occupancy Group R-2 or R-3, threshold heights for sliding and side-hinged exterior doors shall be permitted to be up to 7¾ inches (197 mm) in height if all of the following apply:...
-
1010.1.6 Thresholds
In occupancy Group R-2 or R-3, threshold heights for sliding and side-hinged exterior doors shall be permitted to be up to 7¾ inches (197 mm) in height if all of the following apply:...
-
Sec. 469.102(d)
(d) A public official of a political subdivision who is legally authorized to issue building construction permits may not accept an application for a building construction permit for a building...
-
11B-503.4 Floor and ground surfaces
Changes in level are not permitted. Exception: Slopes not steeper than 1:48 shall be permitted...
-
11B-503.4 Floor and ground surfaces
Changes in level are not permitted. Exception: Slopes not steeper than 1:48 shall be permitted....
-
502.4 Floor or Ground Surfaces
Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted. Advisory 502.4 Floor or Ground Surfaces....
-
502.4 Floor or Ground Surfaces
Changes in level are not permitted. [ECTCR UFAS 4.6.3] EXCEPTION: Slopes not steeper than 1:48 shall be permitted. Advisory 502.4 Floor or Ground Surfaces....
-
503.4 Floor and Ground Surfaces
Changes in level are not permitted. [ECTCR UFAS 4.6.5] EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
-
Vertical Clearance: ADA Standard Section 307.4
Section 307.4 covers the current ADA Standards for vertical clearance.
-
11B-809.5.5.2 Identification
Such peepholes can be placed at a standard height and permit a view from several feet from the door. ◼...