Button spacing shall comply with Section 11B-407.4.7.1.5.
Search Results "Elevator Car Door"
Commonly Searched Documents
-
11B-411.4.7.4 Button spacing
-
11B-407.4.6.2.1 Size and shape
11B-407.4.6.2.1 Size and shape. Buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in their smallest dimension and be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch...
-
11B-407.4.6.2.2 Arrangement
Buttons shall be arranged with numbers in ascending order. When two or more columns of buttons are provided they shall read from left to right.
-
11B-407.4.6.2.2 Arrangement
Buttons shall be arranged with numbers in ascending order. When two or more columns of buttons are provided they shall read from left to right.
-
11B-407.4.6.2.1 Size and shape
11B-407.4.6.2.1 Size and shape. Buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in their smallest dimension and be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch...
-
11B-411.4.7.4 Button spacing
Button spacing shall comply with Section 11B-407.4.7.1.5.
-
11B-411.4.6.1 Location
Controls shall be located within one of the reach ranges specified in Section 11B-308.
-
11B-411.4.7.1 Type
Control button type shall comply with Section 11B-407.4.7.1.1.
-
11B-407.4.8.1.4 Reserved.
In destination-oriented elevators, a display shall be provided in the car with visible indicators to show car destinations....
-
11B-407.4.8.1.4 Reserved
In destination-oriented elevators, a display shall be provided in the car with visible indicators to show car destinations....
-
§ 38.93 Doorways
[56 FR 45756, Sept. 6, 1991, as amended at 76 FR 57939, Sept. 19, 2011]
-
11B-410.6 Doors and gates
Platform lifts shall have low-energy power-operated doors or gates complying with Section 11B-404.3. Doors shall remain open for 20 seconds minimum....
-
11B-407.4.8.2.2 Signal level
The verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the annunciator.
-
408.4.1 Car Dimensions and Doors
408.4.1 Car Dimensions and Doors. Elevator cars shall provide a clear width 42 inches (1065 mm) minimum and a clear depth 54 inches (1370 mm) minimum....
-
11B-206.5 Doors, doorways, and gates
Doors, doorways, and gates providing user passage shall be provided in accordance with Section 11B-206.5....
-
11B-404.2.6 Doors in series and gates in series
The distance between two hinged or pivoted doors in series and gates in series shall be 48 inches (1219 mm) minimum plus the width of doors or gates swinging into the space....
-
PASSENGER ELEVATOR
[DSA-AC] See “Elevator, Passenger”....
-
ELEVATOR, PASSENGER
[DSA-AC] An elevator used primarily to carry passengers....
-
Elevators: ADA Standard Section 206.6
Section 206.6 covers scoping requirements in the most current ADA Standards for accessible routes to elevators.
-
407.4 Elevator Car Requirements
Elevator cars shall comply with 407.4....
-
407.4 Elevator Car Requirements
Elevator cars shall comply with 407.4....
-
408.4.1 Car Dimensions and Doors
Elevator cars shall provide a clear width 42 inches (1065 mm) minimum and a clear depth 54 inches (1370 mm) minimum....
-
Guest Room Doors and Doorways: ADA Standard Section 224.1.2
Section 224.1.2 covers scoping requirements in the current ADA Standards for transient lodging guest room doors and doorways.
-
Double-Leaf Doors and Gates: ADA Standard Section 404.2.2
Section 404.2.2 covers the current ADA Standards for double-leaf doors and gates that are part of an accessible route.