407.3 Elevator Door Requirements
Hoistway and car doors shall comply with 407.3....
-
407.3.1 Type
Elevator doors shall be the horizontal sliding type. Car gates shall be prohibited....
-
407.3.2 Operation
Elevator hoistway and car doors shall open and close automatically....
-
407.3.3 Reopening Device
Elevator doors shall be provided with a reopening device complying with 407.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed by an...
-
407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (125 mm) nominal and 29 inches (735 mm) nominal above the finish floor.
-
407.3.3.2 Contact
The device shall not require physical contact to be activated, although contact is permitted to occur before the door reverses....
-
407.3.3.3 Duration
Door reopening devices shall remain effective for 20 seconds minimum....
-
407.3.4 Door and Signal Timing
The minimum acceptable time from notification that a car is answering a call or notification of the car assigned at the means for the entry of destination information until the doors of...
-
407.3.5 Door Delay
Elevator doors shall remain fully open in response to a car call for 3 seconds minimum....
-
407.3.6 Width
The width of elevator doors shall comply with Table 407.4.1. EXCEPTION: In existing elevators, a power-operated car door complying with 404.2.3 shall be permitted....
-
407.4.1 Car Dimensions
Inside dimensions of elevator cars and clear width of elevator doors shall comply with Table 407.4.1....
-
408.3 Elevator Doors
Elevator hoistway doors shall comply with 408.3....
-
408.3.1 Sliding Doors
Sliding hoistway and car doors shall comply with 407.3.1 through 407.3.3 and 408.4.1....
-
408.3.2 Swinging Doors
Swinging hoistway doors shall open and close automatically and shall comply with 404, 407.3.2 and 408.3.2....
-
408.3.2.1 Power Operation
Swinging doors shall be power-operated and shall comply with ANSI/BHMA A156.19 (1997 or 2002 edition) (incorporated by reference, see "Referenced Standards" in Chapter 1)....
-
408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated....
-
409.3 Elevator Doors
Hoistway doors, car doors, and car gates shall comply with 409.3 and 404....
-
409.3.1 Power Operation
Elevator car and hoistway doors and gates shall be power operated and shall comply with ANSI/BHMA A156.19 (1997 or 2002 edition) (incorporated by reference, see "Referenced Standards" in...
-
409.3.2 Location
Elevator car doors or gates shall be positioned at the narrow end of the clear floor spaces required by 409.4.1....
-
4.1.6(3)(c)(i)
(i) If safety door edges are provided in existing automatic elevators, automatic door reopening devices may be omitted (see 4.10.6)....
-
4.1.6(4)(c)
(c) Elevators. (i) If a safety door edge is provided in existing automatic elevators, then the automatic door reopening devices may be omitted (see 4.10.6)....
-
Must elevator doors remain open for 20 seconds?
LULA swing doors, private residence elevator doors, and platform lift gates and doors must remain open for 20 seconds minimum....