Private residence elevator cars shall comply with Section 11B-409.4....
Search Results "Elevator Car Door"
-
11B-409.4 Elevator cars
-
407.4.8.1.2 Location
Indicators shall be located above the car control panel or above the door....
-
11B-411.2.3.2 Car designation signs
Car designation signs complying with Sections 11B-703.2 and 11B-703.4.1 shall be provided on both jambs of the hoistway immediately below the floor designation....
-
11B-411.2.3.2 Car designation signs
Car designation signs complying with Sections 11B-703.2 and 11B-703.4.1 shall be provided on both jambs of the hoistway immediately below the floor designation....
-
11B-404.2.4.2 Doorways without doors or gates, sliding doors, and folding doors
Doorways less than 36 inches (914 mm) wide without doors or gates, sliding doors, or folding doors shall have maneuvering clearances complying with Table 11B-404.2.4.2....
-
11B-404.2.4.2 Doorways without doors or gates, sliding doors, and folding doors
Doorways less than 36 inches (914 mm) wide without doors or gates, sliding doors, or folding doors shall have maneuvering clearances complying with Table 11B-404.2.4.2....
-
11B-411.1.2 Car designations
Elevator cars shall be designated with a single alphabetic character....
-
11B-411.1.2 Car designations
Elevator cars shall be designated with a single alphabetic character....
-
11B-411.2.1.2.4.2 Size
Elevator assignment characters shall be 1 inch high (25 mm) minimum....
-
11B-411.2.1.2.4.2 Size
Elevator assignment characters shall be 1 inch high (25 mm) minimum....
-
11B-411.1.2 Car designations
Elevator cars shall be designated with a single alphabetic character....
-
Power Operation: ADA Standard Section 408.3.2.1
Section 408.3.2.1 covers the current ADA Standards for the power operation of swinging doors on limited-use/limited-application elevators.
-
407.4.8.1.3 Floor Arrival
As the car passes a floor and when a car stops at a floor served by the elevator, the corresponding character shall illuminate....
-
407.4.8.1.3 Floor Arrival
As the car passes a floor and when a car stops at a floor served by the elevator, the corresponding character shall illuminate....
- Mitsubishi Elevator Group Control System Replacement Panels
-
407.4.8.1.3 Floor Arrival
As the car passes a floor and when a car stops at a floor served by the elevator, the corresponding character shall illuminate....
-
11B-407.4.8.1.3 Floor arrival
As the car passes a floor and when a car stops at a floor served by the elevator, the corresponding character shall illuminate. Exception: Reserved....
-
11B-407.4.8.1.3 Floor arrival
As the car passes a floor and when a car stops at a floor served by the elevator, the corresponding character shall illuminate. Exception: Reserved....
- Otis Elevator Braille and Safety Signs
-
11B-407.4.8.1.3 Floor arrival
As the car passes a floor and when a car stops at a floor served by the elevator, the corresponding character shall illuminate. Exception: Reserved....
-
11B-407.4.7.1.5 Button spacing
A minimum clear space of 3/8 inch (9.5 mm) or other suitable means of separation shall be provided between rows of control buttons.
-
11B-407.4.7.1.1 Type
Control buttons shall be identified by raised characters or symbols, white on a black background, complying with Section 11B-703.2 and Braille complying with Section...
-
11B-407.4.7.1.1 Type
Control buttons shall be identified by raised characters or symbols, white on a black background, complying with Section 11B-703.2 and Braille complying with Section...
-
11B-407.4.7.1.5 Button spacing
A minimum clear space of 3/8 inch (9.5 mm) or other suitable means of separation shall be provided between rows of control buttons.