The visible indication shall extinguish when the car arrives at the designated floor....
Search Results "Elevator Car Door"
Commonly Searched Documents
-
407.4.7.1.4 Visible Indicators
-
4.10.13* Car Position Indicators
In elevator cars, a visual car position indicator shall be provided above the car control panel or over the door to show the position of the elevator in the hoistway....
-
4.10.13* CAR POSITION INDICATORS
In elevator cars, a visual car position indicator shall be provided above the car control panel or over the door to show the position of the elevator in the hoistway....
-
Doors: ADA Standard Section 604.8.1.2
Section 604.8.1.2 covers the current ADA Standards for wheelchair accessible compartment doors.
-
Location: ADA Standard Section 407.4.6.4.2
Section 407.4.6.4.2 covers the current ADA Standards for the location of the emergency controls in elevator cars.
- Symmetry Limited Use/Limited Application (LU/LA) Elevator
-
11B-404.3.7 Revolving doors, revolving gates, and turnstiles
Revolving doors, revolving gates, and turnstiles shall not be part of an accessible route....
-
407.2.3.2 Car Designations
407.2.3.2 Car Designations....
-
11B-404.2.9 Door and gate opening force
The force for pushing or pulling open a door or gate shall be as follows: [2010 ADA Standards] 404.2.9 Door and Gate Opening Force....
-
407.2.3.2 Car Designations
Destination-oriented elevators shall provide tactile car identification complying with 703.2 on both jambs of the hoistway immediately below the floor designation....
-
4.10.12(1)
(1) Buttons. All control buttons shall be at least 3/4 in (19 mm) in their smallest dimension. They shall be raised or flush.
-
4.10.12(1)
(1) Buttons. All control buttons shall be at least 3/4 in (19 mm) in their smallest dimension. They may be raised or flush.
-
4.10.12(4)
Controls shall be located on a front wall if cars have center opening doors, and at the side wall or at the front wall next to the door if cars have side opening doors (see Fig. 23(c) and...
-
4.10.12(4)
Controls shall be located on a front wall if cars have center opening doors, and at the side wall or at the front wall next to the door if cars have side opening doors (see Fig. 23(c) and...
-
Elevator Car Requirements [§407.4]
Elevator Car Requirements [§407.4] The ADA Standards specify the minimum car dimensions....
-
11B-407.4.6.4.1 Height
Emergency control buttons shall have their centerlines 35 inches (889 mm) minimum above the finish floor.
-
11B-407.4.8.2.3 Frequency
The verbal annunciator shall have a frequency of 300 Hz minimum to 3000 Hz maximum.
-
A4.10.12 CAR CONTROLS
Industry-wide standardization of elevator control panel design would make all elevators significantly more convenient for use by people with severe visual impairments....
-
A4.10.12 Car Controls
Industry-wide standardization of elevator control panel design would make all elevators significantly more convenient for use by people with severe visual impairments....
-
11B-604.8.2.2 Doors
Toilet compartment doors, including door hardware, shall comply with Section 11B-404, except that if the approach is to the latch side of the compartment door, clearance between the door...
-
11B-604.8.1.2 Doors
Toilet compartment doors, including door hardware, shall comply with Section 11B-404 except that if the approach is from the push side of the compartment door, clearance between the door...
- Elvoron LU/LA - Limited Use / Limited Application Hydraulic Elevator
- Otis Elevator Advanced Lantern Retrofit
-
11B-404.2.8.1 Door closers and gate closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...