In elevator cars, a visual car position indicator shall be provided above the car control panel or over the door to show the position of the elevator in the hoistway....
Search Results "Elevator Car Door"
Commonly Searched Documents
-
4.10.13* CAR POSITION INDICATORS
-
11B-407.4.7.1.4 Visible indicators
The visible indication shall extinguish when the car arrives at the designated floor....
-
407.4.7.1.4 Visible Indicators
The visible indication shall extinguish when the car arrives at the designated floor....
-
407.4.7.1.4 Visible Indicators
The visible indication shall extinguish when the car arrives at the designated floor....
-
11B-407.4.7.1.4 Visible indicators
The visible indication shall extinguish when the car arrives at the designated floor....
-
11B-407.4.7.1.4 Visible indicators
The visible indication shall extinguish when the car arrives at the designated floor....
-
407.4.7.1.4 Visible Indicators
The visible indication shall extinguish when the car arrives at the designated floor....
-
Location: ADA Standard Section 407.4.6.4.2
Section 407.4.6.4.2 covers the current ADA Standards for the location of the emergency controls in elevator cars.
-
407.2.3.2 Car Designations
407.2.3.2 Car Designations....
-
11B-404.2.8.1 Door closers and gate closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
407.2.3.2 Car Designations
Destination-oriented elevators shall provide tactile car identification complying with 703.2 on both jambs of the hoistway immediately below the floor designation....
-
4.10.12(1)
(1) Buttons. All control buttons shall be at least 3/4 in (19 mm) in their smallest dimension. They shall be raised or flush.
-
4.10.12(1)
(1) Buttons. All control buttons shall be at least 3/4 in (19 mm) in their smallest dimension. They may be raised or flush.
-
4.10.12(4)
Controls shall be located on a front wall if cars have center opening doors, and at the side wall or at the front wall next to the door if cars have side opening doors (see Fig. 23(c) and...
-
4.10.12(4)
Controls shall be located on a front wall if cars have center opening doors, and at the side wall or at the front wall next to the door if cars have side opening doors (see Fig. 23(c) and...
-
A4.10.12 CAR CONTROLS
Industry-wide standardization of elevator control panel design would make all elevators significantly more convenient for use by people with severe visual impairments....
-
A4.10.12 Car Controls
Industry-wide standardization of elevator control panel design would make all elevators significantly more convenient for use by people with severe visual impairments....
-
Elevator Car Requirements [§407.4]
Elevator Car Requirements [§407.4] The ADA Standards specify the minimum car dimensions....
-
11B-407.4.6.4.1 Height
Emergency control buttons shall have their centerlines 35 inches (889 mm) minimum above the finish floor.
-
11B-407.4.8.2.3 Frequency
The verbal annunciator shall have a frequency of 300 Hz minimum to 3000 Hz maximum.
- Elvoron LU/LA - Limited Use / Limited Application Hydraulic Elevator
-
Illumination Levels: ADA Standard Section 409.4.5
Section 409.4.5 covers the current ADA Standards for the illumination of the elevator car in private residence elevators.
-
407.2.3.2 Car Designations
Destination-oriented elevators shall provide tactile car identification complying with 703.2 on both jambs of the hoistway immediately below the floor designation....
-
§ 38.93(a)(2)
(2) If doorways connecting adjoining cars in a multi-car train are provided, and if such doorway is connected by an aisle with a minimum clear width of 30 inches to one or more spaces where...