Control button type shall comply with Section 11B-407.4.7.1.1.
Search Results "Car Lift"
-
11B-411.4.7.1 Type
-
11B-407.4.6.2.2 Arrangement
Buttons shall be arranged with numbers in ascending order. When two or more columns of buttons are provided they shall read from left to right.
-
11B-411.4.7.4 Button spacing
Button spacing shall comply with Section 11B-407.4.7.1.5.
-
11B-411.4.7.1 Type
Control button type shall comply with Section 11B-407.4.7.1.1.
-
11B-411.4.6.1 Location
Controls shall be located within one of the reach ranges specified in Section 11B-308.
-
11B-407.4.6.2.1 Size and shape
11B-407.4.6.2.1 Size and shape. Buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in their smallest dimension and be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch...
-
Where Platform Lifts are Permitted [§206.7]
Where Platform Lifts are Permitted [§206.7] Platform lifts can be part of an accessible route in existing facilities that are altered....
-
S.R. Smith aXs Pool Lift Video 4: Pool Lift Maintenance and Cleaning
Requires the Registered User plan or above. Login!
-
17. I’ve provided a pool lift. Do I have any further legal obligations?
I’ve provided a pool lift. Do I have any further legal obligations?...
-
409.4.6 Car Controls
409.4.6 Car Controls. Elevator car control buttons shall comply with 409.4.6, 309.3, 309.4, and shall be raised or flush....
- EZ-ACCESS PASSPORT® Vertical Platform Lift Video
-
Portable Floor Lifts
Portable Floor Lifts The most common types of lifts in medical settings are portable with a U-shaped base that moves along the floor on wheels....
-
4.10.12* Car Controls
Elevator control panels shall have the following features:
-
4.10.12* CAR CONTROLS
Elevator control panels shall have the following features:
-
6. What if I can’t afford to install a fixed lift in my pool, or it would be difficult to do so?
What if I can’t afford to install a fixed lift in my pool, or it would be difficult to do so? In that case, installation is not required....
-
Team or Player Seating: ADA Standard Section 206.7.9
Section 206.7.9 covers the most current ADA Standards for platform lifts used to connect accessible routes to team or player seating
- Pro Pool Series, Ranger, Pathfinder, Patriot: Troubleshooting When Lift Does Not Move, Lift Is Silent
-
11B-207.2 Platform lifts
Standby power shall be provided for platform lifts permitted by Chapter 10, Section 1007.5 to serve as a part of an accessible means of egress....
-
11B-207.2 Platform lifts
Standby power shall be provided for platform lifts permitted by Chapter 10, Section 1009.5 to serve as a part of an accessible means of egress....
-
11B-207.2 Platform lifts
Standby power shall be provided for platform lifts permitted by Chapter 10, Section 1009.5 to serve as a part of an accessible means of egress....
-
11B-206.7.9 Team or player seating
Platform lifts shall be permitted to provide accessible routes to team or player seating areas serving areas of sport activity. Advisory 11B-206.7.9 Team or player seating....
-
11B-206.7.9 Team or player seating
Platform lifts shall be permitted to provide accessible routes to team or player seating areas serving areas of sport activity. Advisory 11B-206.7.9 Team or player seating....
-
Lift Compatibility (M301.4 and M302.4)
Portable floor lifts have legs with wheels that need to fit under or around the base of the diagnostic equipment....
-
11B-410.7 Landing size
The minimum size of landings at platform lifts shall be 60 inches by 60 inches (1524 mm by 1524 mm)....