Hand operated flush controls shall comply with 309.2 and 309.4 and shall be installed 36 inches (915 mm) maximum above the finish floor....
Search Results "Floor Slope"
Commonly Searched Documents
-
Flush Controls on Toilets
-
Side reach (Section-by-Section Analysis)
The table accompanying section 217.2 of the 2010 Standards makes clear that where one or more telephones are provided on a floor, level, or an exterior site, only one phone per floor, level...
-
Section 36.406(e) Housing at a Place of Education (Section-by-Section Analysis)
There are other differences between the two sets of standards, including requirements for accessible windows, alterations, kitchens, an accessible route throughout a unit, and clear floor...
-
Side reach (Section-by-Section Analysis)
The table accompanying section 217.2 of the 2010 Standards makes clear that, where one or more telephones are provided on a floor, level, or an exterior site, only one phone per floor, level...
- Hoyer Journey Stand-Up Lift
- Bradley Advocate AV-Series AV30 Lavatory, Soap & Hand Dryer
- Hoyer Ascend Stand-Up Lift
- American Specialties 9012 Surface Mounted Baby Changing Station
- Tork Elevation® High Capacity Bath Tissue Roll Dispenser, White
- Tork Elevation® High Capacity Bath Tissue Roll Dispenser, Black
- Locus Labs Inc. LocusMaps SDK
-
ADA Standards for Accessible Design Pocket Guide: ADA Standard Section 2010
The complete guide to the 2010 ADA Standards for Accessible Design with notes provided by national accessibility experts Evan Terry Associates
-
11B-224.7.2 Multi-bedroom housing units with adaptable features
Kitchens within housing units containing accessible sleeping rooms with mobility features (including suites and clustered sleeping rooms) or on floors containing accessible sleeping rooms...
-
INTRODUCTION
Running, cross, and side slopes of curb ramps that are excessively steep; ii. Ramps that are too narrow to accommodate wheelchairs or scooters; iii....
-
233 Residential Facilities
(1) In sleeping rooms with more than 25 beds covered by this section, a minimum of 5% of the beds shall have clear floor space complying with section 806.2.3 of the 2010 Standards....
-
11B-205.1 General
Floor electrical receptacles shall not be required to comply with Section 11B-309. 5. HVAC diffusers shall not be required to comply with Section 11B-309. 6. ...
-
Accessible Fishing Piers and Platforms
If railings, guards, or handrails are provided, accessible edge protection and clear floor or ground space at accessible railings are required....
-
Kitchen Appliances
Section 309 includes specifications for clear floor space (309.2), height (309.3), and operating characteristics (309.4)....
-
11B-233.3.4.1 Alterations to vacated buildings
Exception: Where any portion of a building’s exterior is preserved, but the interior of the building is removed, including all structural portions of floors and ceilings and a new building...
-
1136A.2 Switch and control heights
located no more than 48 inches (1219 mm) measured from the top of the outlet box nor less than 15 inches (381 mm) measured from the bottom of the outlet box to the level of the finished floor...
-
1117B.1, Item 5
The bubbler outlet orifice shall be located within 6 inches (152mm) of the front edge of the drinking fountain and within 36 inches (914 mm) of the floor....
-
1117B.1, Item 4
The bubbler outlet orifice shall be located within 6 inches (152mm) of the front edge of the drinking fountain and within 36 inches (914 mm) of the floor....
-
Alterations
The seat of at least one spring rocker is between 11 inches (280 mm) and 24 inches (610 mm) maximum, and clear floor or ground space and maneuvering space is provided. ...
-
Wheelbase Definition
Wheelbase Definition For the purpose of this analysis, wheelbase is defined as the distance from the center of the primary drive wheel to the center of the caster measured parallel to the floor...