The use of alternative designs or technologies that result in substantially equivalent or greater accessibility and usability than specified in the standards is permitted....
Search Results "Floor Designation"
-
M101.3 Equivalent Facilitation
-
CHILDREN’S USE
[DSA-AC] Describes spaces and elements specifically designed for use primarily by people 12 years old and younger....
-
CHILDREN’S USE
[DSA-AC] Describes spaces and elements specifically designed for use primarily by people 12 years old and younger....
-
11B-1008.4.4 Entry points and seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (279 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
-
Turning Space
The space may overlap the accessible route and clear floor or ground space....
-
802.1.4 Approach
Because accessible routes serving wheelchair spaces are not permitted to overlap the clear floor space at wheelchair spaces, access to any wheelchair space cannot be through another wheelchair...
-
904.4.2 Forward Approach
A clear floor or ground space complying with 305 shall be positioned for a forward approach to the counter....
-
904.4.2 Forward Approach
A clear floor or ground space complying with 305 shall be positioned for a forward approach to the counter....
-
Protruding objects and vitrines
aprons, extend bases, or add barriers below objects and vitrines that project more than 4" from walls and have their leading edges greater than 27" and less than 80" above the finished floor...
-
4.17.6 Grab Bars
Grab bars may be mounted with any desired method as long as they have a gripping surface at the locations shown and do not obstruct the required clear floor area....
-
4.30.3 Character Height
Height Above Finished Floor Minimum Character Height Suspended or Projected Overhead in compliance with 4.4.2 3 in (75mm) minimum...
-
4.17.6 GRAB BARS
Grab bars may be mounted with any desired method as long as they have a gripping surface at the locations shown and do not obstruct the required clear floor area....
-
Are accessible spaces required in temporary parking lots and in unpaved lots, such as gravel or grass lots?
parking facilities, including gravel or grass lots, parking spaces and access aisles must be marked and have firm, stable, and slip resistant surfaces as specified for accessible ground and floor...
-
11B-1008.4.4 Entry points and seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (279 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
-
§ 38.107(a)(4)
Controls for flush valves shall be mounted no more than 44 inches above the floor....
-
§ 38.123(a)(4)
Controls for flush valves shall be mounted no more than 44 inches above the floor....
-
§ 38.23(c)(3) Ramp threshold
The transition from roadway or sidewalk and the transition from vehicle floor to the ramp may be vertical without edge treatment up to 1/4 inch....
-
11B.707.7.1.1 Vertically mounted display screen
mounted vertically or tipped away from the viewer less than 30 degrees, the center line of the display screen and other display devices shall be no more than 52 inches (1321 mm) above the floor...
-
11B-1008.4.4 Entry points and seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (279 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
-
Problem One
Solution: Find a relatively level parking area near the accessible entrance and then designate the area for accessible parking spaces and adjacent access aisles. ...
-
3306.2 Walkways
Walkways shall be accessible in accordance with Chapter 11A or 11B as applicable, and shall be designed to support all imposed loads and in no case shall the design live load be less than...
-
F206.3 Location
This means that circulation paths, such as vehicular ways designed for pedestrian traffic, walks, and unpaved paths that are designed to be routinely used by pedestrians must be accessible...
-
4(2)
Except for design features, such as a loft or an area on a different level within a room (e.g., a sunken living room), changes in level greater than 1/2 inch are ramped or have other means...
-
Administrative Requirements
Public entities with 50 or more employees are also required to: Designate an employee to oversee Title II compliance. Establish a grievance procedure....