EXCEPTION: Dining surfaces and work surfaces that are used primarily by children 5 years and younger shall not be required to comply with 902.4 where a clear floor or ground space complying...
Search Results "Floor Designation"
-
902.4 Dining Surfaces and Work Surfaces for Children's Use
-
217.4.1 Bank Requirement
EXCEPTION: TTYs shall not be required at banks of telephones located within 200 feet (61 m) of, and on the same floor as, a bank containing a public TTY....
-
(5) Reinforced walls for grab bars
The only change made to these guidelines has been to subject powder rooms to the reinforced wall requirement when the powder room is the only toilet facility on the accessible floor of a...
-
I. Security
Is the security latch or bolt on the hall door mounted no higher than 48" above the floor so it is within the reach of persons who use wheelchairs and is it operable with one hand, without...
-
D6
If an entry has a vestibule, is there a 30-inch by 48-inch clear floor space inside the vestibule where a wheelchair or scooter user can be outside the swing of a hinged door?...
-
J6
Is the bottom of the apron of the fountain 27 inches above the floor so that it provides the space needed for a person who uses a wheelchair to pull up under it but is not a hazard to people...
-
1132A.4, Item 2
., wood decking with spaces) shall be the same level as the interior landing, except that secondary exterior doors may have no more than ½ inch (12.7 mm) of change in height between floor...
-
804.3.2 Height
The kitchen work surface shall be 34 inches (865 mm) maximum above the finish floor or ground....
-
Forward Approach
Clear floor space must be provided to the face of the unit since the seated forward reach does not extend much beyond the toes....
-
4.7.3 Slope
The slope of the clear floor or ground spaces required by section 4.0 shall not exceed 1:48 (2 percent) in any direction. Exception....
-
Side Reach [§308.3]
The maximum reach depth for this range is 10” measured from the available clear floor space....
-
1132A.4, Item 2
., wood decking with spaces) shall be the same level as the interior landing, except that secondary exterior doors may have no more than ½ inch (12.7 mm) of change in height between floor...
-
§ 38.93(d)(2) Exception
New vehicles operating in existing stations may have a floor height within plus or minus 11/2 inches of the platform height....
-
11B-203.10 Raised refereeing, judging, and scoring areas
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...
-
11B-233.3.1.2.1 Elevator buildings
Residential dwelling units on floors served by an elevator shall be adaptable....
-
11B-203.10 Raised refereeing, judging, and scoring areas
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...
- Panda TS.87 Thermally Broken Slim Profile Lift & Slide System
-
[F] 907.4.2.2 Height
The height of the manual fire alarm boxes shall be a minimum of 42 inches (1067 mm) and a maximum of 48 inches (1219 mm) measured vertically, from the floor level to the activating handle...
-
241 and 612 Saunas and Steam Rooms
Doors are not permitted to swing into the clear floor or ground space for the accessible bench....
-
11B-604.7 Dispensers
The outlet of the dispenser shall be below the grab bar, 19 inches (483 mm) minimum above the finish floor and shall not be located behind grab bars....
-
4.4 Equipment Barriers and Solutions
Low cost Involved / High cost Spaces between the equipment are too narrow Ask staff to move one of each type of equipment to the end of the aisle where there is extra floor...
-
407.12.3.2.2 Knee and Toe Space
Toe space shall be permitted to provide a clear height of 9 inches (230 mm) minimum above the floor and a clear depth of 6 inches (150 mm) maximum from the vertical reference plane toward...
-
11B-404.2.11 Vision lights
gates, containing one or more glazing panels that permit viewing through the panels shall have the bottom of at least one glazed panel located 43 inches (1092 mm) maximum above the finish floor...
-
1015.2 Where required
along open-sided walking surfaces, including mezzanines, equipment platforms, aisles, stairs, ramps and landings that are located more than 30 inches (762 mm) measured vertically to the floor...