Toward that end, the final rule has been revised to include the Department's policy interpretations as outlined in published technical assistance, Commonly Asked Questions about Service...
Search Results "End Transfer Surface"
-
Section 36.302(c) Service Animals (Section-by-Section Analysis)
- Turnstile Security Systems Inc. 6000 GB 1 Optical Turnstile
- Turnstile Security Systems Inc. 6000 GB 2 Optical Turnstile
-
11B-705.1.1.2 Dome spacing
Truncated domes in a detectable warning surface shall have a center-to-center spacing of 2.3 inches (58 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch...
-
Accessible Routes
The accessible route must comply with ADAAG provisions for the location, width (minimum of 36 inches), passing space, head room, surface, slope (maximum of 1:12 or 8.33%), changes in level...
-
11B-606.3 Height
Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34 inches (864 mm) maximum above the finish floor or ground....
-
1017.5 Tread Obstacles
The vertical alignment of joints in concrete, asphalt, or board surfaces on trails can be tread obstacles....
-
Instrumentation for Analysis
Upon installation, the playground owner completed a questionnaire (Appendix B) on the type, size and intended age group of the playground, the total cost for the equipment, surface materials...
-
Additional Technical Criteria Considered for Handrails on Ramps
These technical criteria are available at http://www.access-board.gov/ada-aba/final.cfm#a505 and address continuity, height, clearance, gripping surface, cross section, surfaces, fittings...
-
11B-505.10.3 Bottom extension at stairs
Extension shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent stair flight....
-
11B-606.3 Height
Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34 inches (864 mm) maximum above the finish floor or ground....
-
11B-606.3 Height
Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34 inches (864 mm) maximum above the finish floor or ground....
-
M301.4 Lift Compatibility
provide a clearance 44 inches (1120 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep minimum measured from the edge of the examination surface...
-
Soiltac Liquid Mix-In
The surface is compacted and then sprayed to seal. The stabilizer has a penetration depth of 4 inches. After the first heavy rainfall, the surface seemed to maintain itself well....
-
Slopes and Resting Intervals for Outdoor Recreation Access Routes
, fiberglass, or other manufactured material), it's more difficult to ensure drainage on natural or gravel surfaces....
- TechnoGym® - Recline 500 Exercise Bike (LED)
- Delta Two Handle Widespread Lavatory - Less Grid Strainer 3579LF-WFLGHDF
- TechnoGym® - Recline 700 Exercise Bike (LED)
- Independent Living Center of Southeast Missouri (ILCSEMO) - Poplar Bluff, MO
-
11B-224.8.2 More than 50-bed facilities
Transfer-type showers are not permitted in lieu of a roll-in shower with a seat, and the exceptions in sections 608.3 and 608.4 for residential dwelling units are not permitted. ...
-
11B-224.8.2 More than 50-bed facilities
Transfer-type showers are not permitted in lieu of a roll-in shower with a seat, and the exceptions in sections 608.3 and 608.4 for residential dwelling units are not permitted. ...
-
3.13(a) Placement of Wheelchair Spaces
Placement of Wheelchair Spaces Each wheelchair space shall comply with the size requirements set forth in § 4.33.2 of the Standards, be level and satisfy the floor surface requirements...
-
1009.2.4 Seat Height
The height of the lift seat shall be designed to allow a stop at 16 inches (405 mm) minimum to 19 inches (485 mm) maximum measured from the deck to the top of the seat surface when in the...
-
Landings
Landings Landings are the level surfaces at the top and bottom of each ramp run....