Buildings and other functional areas shall be served by paths or walks with firm and stable surfaces....
Search Results "End Transfer Surface"
-
11B-246.7 Trails and paths
-
11B-1002.4.4.1 Width and length
Wheelchair spaces shall provide a clear width of 30 inches (762 mm) minimum and a clear length of 48 inches (1219 mm) minimum measured to 9 inches (229 mm) minimum above the floor surface...
-
11B-1002.4.4.1 Width and length
Wheelchair spaces shall provide a clear width of 30 inches (762 mm) minimum and a clear length of 48 inches (1219 mm) minimum measured to 9 inches (229 mm) minimum above the floor surface...
-
11B-246.7 Trails and paths
Buildings and other functional areas shall be served by paths or walks with firm and stable surfaces....
-
1009.2.4 Seat Height
The height of the lift seat shall be designed to allow a stop at 16 inches (405 mm) minimum to 19 inches (485 mm) maximum measured from the deck to the top of the seat surface when in the...
-
1002.4.4.1 Width and Length
Wheelchair spaces shall provide a clear width of 30 inches (760 mm) minimum and a clear length of 48 inches (1220 mm) minimum measured to 9 inches (230 mm) minimum above the floor surface...
-
501.1 Scope (Section-by-Section Analysis)
This exception is included because assistive technology frequently needs flexibility in order to perform well for end-users with disabilities....
-
Use of Segways® and Similar Devices by Individuals with a Mobility Impairment in GSA-Controlled Federal Facilities
To that end, on December 3, 2007, GSA's Public Buildings Service issued the following interim policy to permit individuals with a mobility impairment to use these devices in Federal buildings...
-
Paragraph (e) (Advisory Guidance)
Although it may not be achievable with current technology, an alternate strategy might be to recognize the tones, transmit them as codes, and resynthesize them at the other end....
-
Section 1193.33 Accessibility and usability
description of the accessibility and compatibility features of the product upon request, including, as needed, in alternate formats or alternate modes at no additional charge; (2) provide end-user...
-
Master the Skill of Giving Quick Information on How Best to Assist You
You have to carry me out, wheelchair user evacuation chairs are hung at the top of “stairway two, north end” and “stairway three, south end.”...
-
Appendix E to Part 37—Reasonable Modification Requests
These underlying provisions tell entities the end they must achieve; the reasonable modification provision tells entities how to achieve that end in situations in which normal policies and...
-
303 Changes in Level
Section 303 addresses vertical changes in level in floor or ground surfaces. No changes have been made to this section....
-
12162(a)(4)(B)(ii)
(ii) appropriate auxiliary aids and services, including a hard surface on which to eat, shall be provided to ensure that other equivalent food service is available to individuals with disabilities...
-
7.4.4.3 Slope
Where the surface is paved or is elevated above the natural ground, the slope shall not be steeper than 1:48 (2 percent) in any direction. ...
-
A4.13.8 Thresholds at Doorways
Thresholds and surface height changes in doorways are particularly inconvenient for wheelchair users who also have low stamina or restrictions in arm movement because complex maneuvering...
-
2.8 Openings
Openings in the surface of ORARs shall be small enough to prevent passage of a 1/2 inch (13 mm) diameter sphere....
-
4.1.7(2)(e)
., books, should be no higher than 44 in (1120 mm) above the floor surface....
-
A4.13.8 THRESHOLDS AT DOORWAYS
Thresholds and surface height changes in doorways are particularly inconvenient for wheelchair users who also have low stamina or restrictions in arm movement, because complex maneuvering...
-
4.32.3 KNEE CLEARANCES
If seating for people in wheelchairs is provided at tables, counters, and work surfaces, knee spaces at least 27 in (685 mm) high, 30 in (760 mm) wide, and 19 in (485 mm) deep shall be provided...
- PEMKO 5 1/8" Thermal Barrier Threshold No. 252X3-FG
- Pemko 252X2_FG Thermal Barrier Threshold
- PEMKO 6 1/8" Thermal Barrier Threshold No. 273X3-FG
- Georgia-Pacific enMotion® Recessed Automated Touchless Towel Dispenser