objects mounted on posts or pylons shall overhang circulation paths 12 inches (305 mm) maximum when located 27 inches (686 mm) minimum and 80 inches (2032 mm) maximum above the finish floor...
Search Results "Clear Floor Area"
-
11B-307.3 Post-mounted objects
-
307.3 Post-Mounted Objects
objects mounted on posts or pylons shall overhang circulation paths 12 inches (305 mm) maximum when located 27 inches (685 mm) minimum and 80 inches (2030 mm) maximum above the finish floor...
-
1(2)(b) Site impracticality due to unusual characteristics
Unusual characteristics include sites located in a federally-designated floodplain or coastal high-hazard area and sites subject to other similar requirements of law or code that the lowest...
-
1015.2 Where required
On raised stage and platform floor areas, such as runways, ramps and side stages used for entertainment or presentations....
-
Protruding Objects on Beach Access Routes
Outdoor accessibility guidelines define protruding objects as constructed features such as signs that extend into the clear width area of a beach access route or resting interval and are...
-
Scope: ADA Standard Section 201.1
Section 201 discusses the scope of the ADA Standards.
-
E2-b
Are pedestrian routes leading to or serving each of the service or activity areas free of overhead objects with the bottom edge lower than 80 inches above the floor?...
-
4.16.5* Flush Controls
Controls for flush valves shall be mounted on the wide side of toilet areas no more than 44 in (1120 mm) above the floor....
-
4.16.5* FLUSH CONTROLS
Controls for flush valves shall be mounted on the wide side of toilet areas no more than 44 in (1120 mm) above the floor....
-
11B-407.2.2.2 Visible signals
Visible signal fixtures shall be centered at 72 inches (1829 mm) minimum above the finish floor or ground....
-
11B-407.2.2.2 Visible signals
Visible signal fixtures shall be centered at 72 inches (1829 mm) minimum above the finish floor or ground....
-
Wheelchair Storage Space
There must be space in or adjacent to load and unload areas for each ride seat designed for transfer or transfer device. The space must be a minimum of 30 inches by 48 inches....
-
Where Platform Lifts are Permitted [§206.7]
In new construction, platform lifts can be used to provide an accessible route to these areas only: wheelchair spaces, performance areas, and speakers’ platforms incidental...
-
Accessible Courtroom Stations
Clear floor space for a forward approach is required for all courtroom stations (judges’ benches, clerks’ stations, bailiffs’ stations, deputy clerks’ stations, court reporters’ stations...
-
607 Bathtubs
Specifications for bathtubs in section 607 address clear floor space, seats, grab bars, operable parts, shower spray units, and enclosures....
-
Saunas and Steam Rooms
Doors cannot swing into any part of the clear floor or ground space required for benches....
-
Exercise machines. (Section-by-Section Analysis)
Sections 206.2.13 and 236 of the 2004 ADAAG require one of each type of fixed exercise machine to meet clear floor space specifications and to be on an accessible route. ...
-
Exercise machines. (Section-by-Section Analysis)
Sections 236 and 206.2.13 of the 2004 ADAAG require one of each type of fixed exercise machine to meet clear floor space specifications and to be on an accessible route....
-
Width [4.7.3] and Surface [4.7.4]
The minimum clear width of a curb ramp is 36 inches, exclusive of flared sides....
-
R302.7 Surfaces
The surface requirements in R302.7 also apply to surfaces at the following accessible elements and spaces that connect to pedestrian access routes: • Clear spaces (see R404.2), including...
-
307.3 Post-Mounted Objects
objects mounted on posts or pylons shall overhang circulation paths 12 inches (305 mm) maximum when located 27 inches (685 mm) minimum and 80 inches (2030 mm) maximum above the finish floor...
-
Table of Contents
Fire Alarm Systems 216 Signs 217 Telephones 218 Transportation Facilities 219 Assistive Listening Systems 220 Automatic Teller Machine and Fare Machines 221 Assembly Areas...
-
Horizontal Exits [IBC §1021 (2003), §1005.3.5 (2000)]
A horizontal exit compartmentalizes a building allowing occupants to exit the area containing the origin of a fire into another portion of the building that is protected by fire-resistance-rated...