this code shall apply to the construction, alteration, relocation, enlargement, replacement, repair, equipment, use and occupancy, location, maintenance, removal and demolition of every building...
Search Results "Fire-Building Surface"
Commonly Searched Documents
-
[A] 101.2 Scope
-
F208.3.1 General
Parking spaces complying with 502 that serve a particular building or facility shall be located on the shortest accessible route from parking to an entrance complying with F206.4....
-
11B-213.3 Plumbing fixtures and accessories
The 2016 California Plumbing Code (CPC), Table 422.1 provides minimum plumbing fixture requirements for new buildings, and changes of occupancy or use in an existing building resulting in...
-
11B-206.5.2 Rooms and spaces
Within a building or facility, every door, doorway or gate serving rooms and spaces complying with this chapter shall comply with Section 11B-404....
-
419.7 Accessibility
ETA Editor's Note California Building Code Chapters 5 through 8 are not adopted by the Division of the State Architect - Access Compliance (DSA-AC), and have been omitted....
-
419.7 Accessibility
ETA Editor's Note California Building Code Chapters 5 through 8 are not adopted by the Division of the State Architect - Access Compliance (DSA-AC), and have been omitted....
-
11B-213.3 Plumbing fixtures and accessories
The 2016 California Plumbing Code (CPC), Table 422.1 provides minimum plumbing fixture requirements for new buildings, and changes of occupancy or use in an existing building resulting in...
-
11B-206.5.2 Rooms and spaces
Within a building or facility, every door, doorway or gate serving rooms and spaces complying with this chapter shall comply with Section 11B-404....
-
Location [4.6.2] and Dispersion
For example, spaces for an out-lying lot can be placed in a lot closer to the building served since accessible spaces must be located on the shortest accessible route to an accessible facility...
-
Location and Signage
Location and Signage ADAAG does not specify where text telephones are to be located on a site or in a building (except in hospitals, airports, and transit stations)....
-
Elevator Exception 1—Section 206.2.3 of the 2010 Standards
The 2010 Standards contain specific exceptions to the general provision requiring at least one accessible route to connect each story and mezzanine in multi-story buildings or facilities...
-
What access do I need?
Access Checklist ◼ I need a bus stop or parking space close to the building. ◼ I need a path with ramps from the parking or bus to the building....
-
For People with Disabilities, Which Circulation Paths Are Usable, Available, and Closest?
These plans should be given to visitors who are blind or have low vision when they enter the building so they can find the exits in an emergency....
-
SHOPPING CENTER (OR SHOPPING MALL)
For the purposes of this section, “shopping center” or “shopping mall” includes a covered mall building. Advisory Definition of SHOPPING CENTER (or SHOPPING MALL). ...
-
7. Path of Travel Requirements and Adjusted Construction Cost
alterations incidental to the primary scope of installing a PV system are included as part of the project, the adjusted construction cost for purposes of complying with the 2013 California Building...
-
Covered Multifamily Dwellings
The Fair Housing Act and its regulations clearly define "covered multifamily dwellings" as buildings consisting of four or more dwelling units, if such buildings have one or more elevators...
-
The Commenters
These commenters included: the Southern Building Code Congress International (SBCCI); the U.S....
-
603.3 Mirrors
Mirrors located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 40 inches (1015 mm) maximum above the finish floor or ground....
-
402 Accessible Routes
Section 402 lists the various elements that can be part of an accessible route: walking surfaces, doorways, ramps, elevators, and platform lifts....
-
603.3 Mirrors
Mirrors located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 40 inches (1015 mm) maximum above the finish floor or ground....
-
903.4 Back Support
Back support shall be 42 inches (1065 mm) long minimum and shall extend from a point 2 inches (51 mm) maximum above the seat surface to a point 18 inches (455 mm) minimum above the seat...
-
11B-603.3 Mirrors
Mirrors located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 40 inches (1016 mm) maximum above the finish floor or ground....
-
603.3 Mirrors
Mirrors located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 40 inches (1015 mm) maximum above the finish floor or ground....
-
603.3 Mirrors
Mirrors located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 40 inches (1015 mm) maximum above the finish floor or ground....