A visual indication acknowledging the establishment of a communications link to authorized personnel must be provided....
Search Results "Floor Destination Indicator"
-
105.2.2 ASME
-
6.2. Scoping Requirements
As the table indicates, the scoping requirements in the final rule (and used in the primary analysis) require fewer captioning and audio description devices....
-
Comparison of Single-User Toilet Room Layouts: 2A, 2B, and 2C
The in-swinging door increases overall room size because it cannot swing over the required clear floor space at any accessible fixture, (see section 4.22.2 of the 1991 Standards)....
-
Components (M303.4)
M303.4.1 would require the height of the breast platform to be 30 inches (760 mm) high minimum and 42 inches (1065 mm) high maximum above the floor when mammography equipment is used by...
-
Weight Scales
Unit costs are presented for wheelchair scales with raised platforms and with flush platforms in the floor....
- Federal Elevator Carelift Wheelchair Lift
- Florestone 35-62H Barrier-Free Shower
- Collapsible Water Retainer Shower Dam for Shower Threshold
- Waterless Co. Urinal Borrego 2103
- Proline Drain
-
THE UNITED STATES OF AMERICA’S STATEMENT OF INTEREST ON THE PARTIES’ MOTIONS FOR SUMMARY JUDGMENT
Defendants have indicated that the unique Hollister store design – including its raised porches, which are covered by a roof, feature a wooden floor, and include furniture and “props” such...
-
11B-604.8.1.2 Doors
Doors shall not swing into the clear floor space or clearance required for any fixture....
-
1132A.8 Hand-activated door hardware
Hand-activated door latching, locking and opening hardware shall be centered between 30 inches (762 mm) and 44 inches (1118 mm) above the floor....
-
Handrail Extensions
If handrail extensions are provided, they do not need to be parallel with the ground or floor surface, since the surface may be moving due to water conditions....
-
308.2.2 Obstructed High Reach
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction....
-
610.2 Bathtub Seats
The top of bathtub seats shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the bathroom finish floor....
-
Openings, Width and Length of Wheelchair Space
Wheelchair spaces must have a clear width of 30 inches minimum and a clear length of 48 inches minimum, measured to at least 9 inches above the floor surface....
-
Adaptability
Rooms need to be designed to provide required clear floor space at fixtures, turning space, and door clearance....
-
Cross Slope and Surfaces [4.8.6]
Ramp surfaces must comply with requirements for ground and floor surfaces and be "stable, firm, and slip-resistant." A specific level of slip-resistance is not mandated....
-
Outdoor Conditions [4.8.8]
Wetness reduces slip-resistance, which is fully characterized not only by the ramp or floor surface but by the material making contact with it....
-
Stacks [8.5]
Stacks [8.5] Elements fixed to stacks, such as ladders, cannot reduce the minimum passage width nor should signs or other elements between 27 to 80 inches above the floor project more...
-
4.1.2(8)
(8) At least one principal entrance at each grade floor level to a building or facility shall comply with 4.14, Entrances....
-
1014.1 General
The technical requirements address the entrance to camp shelters (1014.2), including transfer access (1014.2.1) and roll-in access (1014.2.2); and the floor within camp shelters (1014.3)...