Where existing elements or spaces are altered, each altered element or space shall comply with the applicable requirements of Chapter 2. EXCEPTIONS: 1. Unless required by F202.4,...
Search Results "Single Occupant Structure"
-
F202.3 Alterations
-
11B-222.1 General
Where dressing rooms, fitting rooms, or locker rooms are provided, at least 5 percent, but no fewer than one, of each type of use in each cluster provided shall comply with Section...
-
F222.1 General
Where dressing rooms, fitting rooms, or locker rooms are provided, at least 5 percent, but no fewer than one, of each type of use in each cluster provided shall comply with...
-
Alterations
In alterations, the minimum number is based on the total number of spaces altered or added to a lot. Recommendation: Where a lot is not fully altered, it is recommended that the...
-
4. I understand that a waiver from accessibility requirements may be obtained?
It is possible that a particular degree of accessibility in an alteration might be found to be an "unreasonable hardship", "disproportionate", or "technically infeasible". Such...
-
4.17.3* Size and Arrangement
The size and arrangement of the standard toilet stall shall comply with Fig. 30(a), Standard Stall. Standard toilet stalls with a minimum depth of 56 in (1420 mm) (see Fig. 30(a))...
-
11B-222.1 General
Where dressing rooms, fitting rooms, or locker rooms are provided, at least 5 percent, but no fewer than one, of each type of use in each cluster provided shall comply with Section...
-
11B-222.1 General
Where dressing rooms, fitting rooms, or locker rooms are provided, at least 5 percent, but no fewer than one, of each type of use in each cluster provided shall comply with Section...
-
202.3 Alterations
Where existing elements, spaces, or common use areas are altered, each altered element, space, or common use area shall comply with the applicable requirements of Chapter...
-
222.1 General
222.1 General. Where dressing rooms, fitting rooms, or locker rooms are provided, at least 5 percent, but no fewer than one, of each type of use in each cluster provided shall comply...
-
222.1 General
Where dressing rooms, fitting rooms, or locker rooms are provided, at least 5 percent, but no fewer than one, of each type of use in each cluster provided shall comply with...
-
202.3 Alterations
202.3 Alterations. Where existing elements or spaces or common areas are altered, each altered element, space or area shall comply with the applicable requirements of Chapter 2 and...
-
11B-232.2.1.4 Technically infeasible
Where it is technically infeasible to locate a substitute cell within the same prison site in compliance with Section 11B-232.2.1.3, a substitute cell shall be provided at another...
-
11B-232.2.1.4 Technically infeasible
Where it is technically infeasible to locate a substitute cell within the same prison site in compliance with Section 11B-232.2.1.3, a substitute cell shall be provided at another...
-
X. Alterations
Alterations after January 26, 1992, to existing places of public accommodation and commercial facilities must be accessible to the maximum extent feasible. The architectural...
-
§ 35.151(b)(4) Path of travel
(4) Path of travel. An alteration that affects or could affect the usability of or access to an area of a facility that contains a primary function shall be made so as to ensure...
-
Substitute cells. (Section-by-Section Analysis)
Substitute cells. In the ANPRM, the Department sought public comment about the most effective means to ensure that existing correctional facilities are made accessible to prisoners...
-
§ 35.151(b)(4) Path of travel
(4) Path of travel. An alteration that affects or could affect the usability of or access to an area of a facility that contains a primary function shall be made so as to ensure...
-
3104.2 Separate structures
Buildings connected by pedestrian walkways or tunnels shall be considered to be separate structures....
-
Alterations
Technically infeasible means: “… something that has little likelihood of being accomplished because existing structural conditions would require removing or altering a load-bearing member...
-
§ 35.151(b)(4)(iv)(B)
(B) In choosing which accessible elements to provide, priority should be given to those elements that will provide the greatest access, in the following order—
-
3104.2 Separate structures
Exceptions: … [DSA-AC and HCD 1-AC] For purposes of accessibility in residential facilities as required by Chapters 11A and 11B, structurally connected buildings, buildings...
-
California Water Closet Accessories
Design guidance for locating water closet accessories in single user toilet rooms and best practice placement of the lavatory in new construction giving the owner more options to maintain...
-
11B-202.3 Alterations
Chapter 2, Section 202 defines alteration as “…a change, addition or modification in construction, change in occupancy or use, or structural repair to an existing building or facility. …...