233.3.4 Alterations. Alterations shall comply with 233.3.4. EXCEPTION: Where compliance with 809.2, 809.3, or 809.4 is technically infeasible, or where it is technically...
Search Results "Single Occupant Structure"
-
233.3.4 Alterations
-
4.1.6(2)
(2) Alterations to an Area Containing a Primary Function: In addition to the requirements of 4.1.6(1), an alteration that affects or could affect the usability of or access to an...
-
Toilet Stalls [4.17]
Toilet Stalls [4.17] The standard stall in section 4.17 is wheelchair accessible. Since wheelchair accessible or "standard" stalls are designed to accommodate the broadest range...
-
10.3.2(3)
(3) Where technical infeasability [sic] in existing stations requires the accessible route to lead from the public way to a paid area of the transit system, an accessible fare...
-
4.1.6(3)(d)(i)
(i) Where it is technically infeasible to comply with clear opening width requirements of 4.13.5, a projection of 5/8 in maximum will be permitted for the latch side stop.
-
Slope and Rise [4.8.2]
Slope represents the proportion of vertical rise to horizontal length and can be represented as a ratio (as in ADAAG), percentage, pitch or in...
-
Common Questions (Alterations and Additions)
Common Questions
-
Supplementary Information:
The Fair Housing Amendments Act also made it unlawful to design and construct certain multifamily dwellings for first occupancy after March 13, 1991, in a manner that makes them inaccessible...
-
Section 3. Fair Housing Act Design and Construction Requirements
This section reprints §100.205 (Design and Construction Requirements) from the Department's final rule implementing the Fair Housing Act. A reprint of §100.205 was included to...
-
1002.2 Accessible Routes
In load or unload areas and on amusement rides, where compliance with 405.2 is not structurally or operationally feasible, ramp slope shall be permitted to be 1:8 maximum. 2....
-
1002.2 Accessible Routes
In load or unload areas and on amusement rides, where compliance with 405.2 is not structurally or operationally feasible, ramp slope shall be permitted to be 1:8 maximum. 2....
-
1002.2 Accessible Routes
In load or unload areas and on amusement rides, where compliance with 405.2 is not structurally or operationally feasible, ramp slope shall be permitted to be 1:8 maximum. 2....
-
Changes in Level within a Dwelling Unit
(Definitions for "single-story dwelling unit," "loft," "multistory dwelling unit" and "story" have been included in Section 2 of the final Guidelines.)...
-
233.3.5 Alterations, F233.3.4 Alterations, F233.4.5 Alterations
facilities contain 15 or fewer residential dwelling units, the requirements of 233.3.1.1 and 233.3.2.1 shall apply to the total number of residential dwelling units that are altered under a single...
-
11B-1002.2 Accessible routes
In load or unload areas and on amusement rides, where compliance with Section 11B-405.2 _|Slope|_ is not structurally or operationally feasible, ramp slope shall be permitted to be 1:8 maximum...
-
11B-1002.2 Accessible routes
In load or unload areas and on amusement rides, where compliance with Section 11B-405.2 _|Slope|_ is not structurally or operationally feasible, ramp slope shall be permitted to be 1:8 maximum...
-
11B-1002.2 Accessible routes
Exceptions: In load or unload areas and on amusement rides, where compliance with Section 11B-405.2 is not structurally or operationally feasible, ramp slope shall be permitted...
-
Alterations to Residential Facilities
Applying the general requirements for alterations to housing can result in partially accessible dwelling units where single elements or spaces in dwelling units are altered....
-
11B-202.3 Alterations
No. 94-1109, dated May 10, 1995, the Attorney General for the State of California concluded that seismic strengthening work in an existing building constitutes a “building alteration, structural...
-
11B-202.3 Alterations
No. 94-1109, dated May 10, 1995, the Attorney General for the State of California concluded that seismic strengthening work in an existing building constitutes a “building alteration, structural...
-
4.1.6(4)(e)
Where alterations to existing facilities make strict compliance with 4.22 and 4.23 structurally impracticable, the addition of one "unisex" toilet per floor containing one water closet complying...
-
Safe Harbor
not appear in 2013 CBC, but a similar provision is included in Exception 2 at Section 11B-202.4, excerpted here: 11B-202.4 Path of travel requirements in alterations, additions and structural...
-
Introduction
with the accessibility requirements of the Fair Housing Amendments Act of 1988 (Fair Housing Act) that are applicable to certain multifamily dwellings designed and constructed for first occupancy...
-
F202.2.3 Toilet and Bathing Facilities
EXCEPTION: In alterations to areas serving additions where it is technically infeasible to comply with 603, altering existing toilet or bathing rooms is not required where a single unisex...