Toilet compartment doors, including door hardware, shall comply with 404 except that if the approach is to the latch side of the compartment door, clearance between the door side of the...
Search Results "Shower Door"
-
604.8.1.2 Doors
-
604.8.1.2 Doors
Toilet compartment doors, including door hardware, shall comply with 404 except that if the approach is to the latch side of the compartment door, clearance between the door side of the...
-
11B-610.3.1 Rectangular seats
The rear edge of a rectangular seat shall be 2½ inches (64 mm) maximum and the front edge 15 inches (381 mm) minimum and 16 inches (406 mm) maximum from the seat wall. The side edge...
-
11B-610.3.1 Rectangular seats
The rear edge of a rectangular seat shall be 2½ inches (64 mm) maximum and the front edge 15 inches (381 mm) minimum and 16 inches (406 mm) maximum from the seat wall. The side edge...
-
California/ADA Plan Review Tool - Door Maneuvering Clearances
California/ADA Plan Review Tool - Door Maneuvering Clearances Click here to view/download the pdf "California/ADA Plan Review Tool - Door Maneuvering Clearances" (250 KB) * * * * *...
-
7. Seat Transfer
Are the roll-in showers free of doors that would impede wheelchair transfer onto the seat? [ADA Stds. 4.21.8] Yes __ No __ N/A __ Comments: _______________________________________...
-
Location of Controls
Comments indicated that this specification was not consistent with a corresponding figure showing the location on the side closest to the shower opening. Response....
-
407.3 Elevator Door Requirements
Hoistway and car doors shall comply with 407.3....
-
407.3 Elevator Door Requirements
Hoistway and car doors shall comply with 407.3....
-
4. Shower Wand
Is there an adjustable height hand-held shower wand with at least a 60" long hose provided so persons who bathe from a seated position may wash and rinse with the directional spray?...
-
11B-404.3.7 Revolving doors, revolving gates, and turnstiles
Revolving doors, revolving gates, and turnstiles shall not be part of an accessible route....
-
11B-404.3.7 Revolving doors, revolving gates, and turnstiles
Revolving doors, revolving gates, and turnstiles shall not be part of an accessible route....
-
11B-404.3.7 Revolving doors, revolving gates, and turnstiles
Revolving doors, revolving gates, and turnstiles shall not be part of an accessible route....
-
11B-608.2.1 Reserved
ETA Editor's Note The transfer type shower compartments prescribed by 2010 ADAS 608.2.1 are not recognized as an accessible shower in California....
-
11B-404.3 Automatic and power-assisted doors and gates
Automatic doors and automatic gates shall comply with Section 11B-404.3. Full-powered automatic doors shall comply with ANSI/BHMA A156.10 ....
-
404.2.8.1 Door Closers and Gate Closers
404.2.8.1 Door Closers and Gate Closers....
-
409.3 Elevator Doors
409.3 Elevator Doors. Hoistway doors, car doors, and car gates shall comply with 409.3 and 404....
-
608.2.3 Alternate Roll-In Type Shower Compartments
Alternate roll-in type shower compartments shall be 36 inches (915 mm) wide and 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
4.23.2 Doors
Doors to accessible bathrooms shall comply with 4.13. Doors shall not swing into the floor space required for any fixture....
-
4.23.2 DOORS
Doors to accessible bathrooms shall comply with 4.13. Doors shall not swing into the floor space required for any fixture....
-
11B-404.2.9 Door and gate opening force
The force for pushing or pulling open a door or gate shall be as follows: [2010 ADAS] 404.2.9 Door and Gate Opening Force. ...
-
409.3 Elevator Doors
Hoistway doors, car doors, and car gates shall comply with 409.3 and 404....
-
409.3 Elevator Doors
Hoistway doors, car doors, and car gates shall comply with 409.3 and 404....
-
11B-404.2.9 Door and gate opening force
The force for pushing or pulling open a door or gate shall be as follows: [2010 ADAS] 404.2.9 Door and Gate Opening Force....