11B-223.1.1 Alterations
Where patient bedrooms or resident sleeping rooms are altered or added, the requirements of Section 11B-223 shall apply only to the patient bedrooms or resident sleeping rooms being altered...
-
11B-223.1.1 Alterations
Where patient bedrooms or resident sleeping rooms are altered or added, the requirements of Section 11B-223 shall apply only to the patient bedrooms or resident sleeping rooms being altered...
-
Work Areas
Work Areas Storage facilities used by employees for purposes other than job-related tasks, such as break room cabinets and shower room lockers, are required to be accessible....
-
Play Area
Play Area - A portion of a site containing play components designed and constructed for children....
- 902.3 Baby Changing Table Work Surface Height
-
11B-1002.3 Load and unload areas
A turning space complying with Sections 11B-304.2 and 11B-304.3 shall be provided in load and unload areas....
-
11B-1002.3 Load and unload areas
A turning space complying with Sections 11B-304.2 and 11B-304.3 shall be provided in load and unload areas....
-
M301.4 Lift Compatibility (Section-by-Section Analysis)
The MDE NPRM proposed to require that diagnostic equipment used by patients in the supine, prone, or side-lying position be usable with a patient lift and comply with either the proposed...
-
1131A.2 Changes greater than ½ inch
1131A.2 Changes greater than ½ inch. ...
-
2) Where the Standard says "Changes in level are not permitted"
2) Where the Standard says "Changes in level are not permitted", such as 304.2 for turning spaces: Here the standard is followed by an unenforceable advisory that says, "As used in this...
-
5.4.4.1 Transfer Support Distance from Transfer Surface for Stretchers
The horizontal distance from the transfer surface should be no more than 3 inches from the edge of the patient support surface....
-
M301.2.3 Transfer Sides
The location of the Transfer Side will be located on the patient right or patient left at roughly midway between the foot end and head end....
-
805 Medical Care and Long-Term Care Facilities
Section 805 addresses access to patient or resident sleeping rooms in medical care and long-term care facilities....
-
M302.3.2 Armrests
Where diagnostic equipment is used by patients in a seated position, armrests shall be provided. Advisory M302.3.2 Armrests....
-
5.4.1.2 Transfer and Positioning Support Location Recommendations for Imaging Equipment with Transfer Surfaces
For wider tables, a transfer support would not be functional because of its distance from the patient....
-
M301.1 General
Where diagnostic equipment is used by patients in a supine, prone, or side-lying position, it shall comply with M301....
-
5.7.1.1 Lift Compatibility Clearance in Base for Stretchers (M301)
The change harmonizes this provision with the international standards. IEC 60601-2-52 provides requirements for stretchers and includes a lift clearance at the 39 inch width....