Section 606.2 covers the current ADA Standards for clear floor space at lavatories and sinks.
Search Results "Finished Grade"
-
Clear Floor Space: ADA Standard Section 606.2
-
11B-604.8.1.4 Toe clearance
At least one side partition shall provide a toe clearance of 9 inches (229 mm) minimum above the finish floor and 6 inches (152 mm) deep minimum beyond the compartment-side face of the partition...
-
11B-604.8.1.4 Toe clearance
At least one side partition shall provide a toe clearance of 9 inches (229 mm) minimum above the finish floor and 6 inches (152 mm) deep minimum beyond the compartment-side face of the partition...
-
Height: ADA Standard Section 407.4.6.4.1
Section 407.4.6.4.1 covers the current ADA Standards for the height of the emergency controls in elevator cars.
-
11B-407.4.6.4.1 Height
Emergency control buttons shall have their centerlines 35 inches (889 mm) minimum above the finish floor....
-
11B-407.4.6.4.1 Height
Emergency control buttons shall have their centerlines 35 inches (889 mm) minimum above the finish floor....
-
11B-609.4 Position of grab bars
Grab bars shall be installed in a horizontal position, 33 inches (838 mm) minimum and 36 inches (914 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
11B-609.4 Position of grab bars
Grab bars shall be installed in a horizontal position, 33 inches (838 mm) minimum and 36 inches (914 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
1.1.7.3.1 Detached one- and two-family dwellings
Detached one- and two-family dwellings, lodging houses, live/work units, townhouses not more than three stories above grade plane in height with a separate means of egress, and their accessory...
-
Vertical Alignment-Crest Vertical Curves
higher grades, many bicyclists may have difficulty climbing and they may end up going downhill too fast for comfort or safe operation....
-
11B-809.9.5 Lower shelving
Lower shelving and/or drawer space shall be provided at a height of 48 inches (1219 mm) maximum above the finish floor....
-
11B-809.10.8.3 Cabinets
The finished floor shall extend to the wall under the lavatory....
-
11B-809.10.8.3 Cabinets
The finished floor shall extend to the wall under the lavatory....
-
11B-809.9.5 Lower shelving
Lower shelving and/or drawer space shall be provided at a height of 48 inches (1219 mm) maximum above the finish floor....
-
Vision Lights: ADA Standard Section 404.2.11
Section 404.2.11 covers the current ADA Standards for vision lights on manual doors and gates.
-
Seats: ADA Standard Section 604.4
Section 604.4 covers the current ADA Standards for the water closet seats.
-
11B-606.2 Clear floor space
floor extends under the cabinetry; and (c) the walls behind and surrounding the cabinetry are finished. 4....
-
11B-606.2 Clear floor space
floor extends under the cabinetry; and (c) the walls behind and surrounding the cabinetry are finished. 4....
-
Ground Floor
Any occupiable floor less than one story above or below grade with direct access to grade....
-
Height: ADA Standard Section 902.4.2
The tops of tables and counters shall be 26 inches (660 mm) minimum and 30 inches (760 mm) maximum above the finish floor or ground....
-
Tray Slides: ADA Standard Section 904.5.2
The tops of tray slides shall be 28 inches (710 mm) minimum and 34 inches (865 mm) maximum above the finish floor or ground....
-
11B-904.5.2 Tray slides
The tops of tray slides shall be 28 inches (711 mm) minimum and 34 inches (864 mm) maximum above the finish floor or ground....
-
11B-902.4.2 Height
The tops of tables and counters shall be 26 inches (660 mm) minimum and 30 inches (762 mm) maximum above the finish floor or ground....
-
11B-902.4.2 Height
The tops of tables and counters shall be 26 inches (660 mm) minimum and 30 inches (762 mm) maximum above the finish floor or ground....