The clear floor space shall be positioned for parallel approach to the side of the bed....
Search Results "Approach"
Commonly Searched Documents
-
806.2.3 Sleeping Areas
-
4.10.12(3)
All floor buttons shall be no higher than 54 in (1370 mm) above the finish floor for side approach and 48 in (1220 mm) for front approach....
- Bobrick Swing-Up Grab Bar B-4998.99
-
11B-809.10.8.1 Location
Lavatories without base cabinets shall be installed with the centerline 18 inches (457 mm) minimum from an adjoining wall or fixture to allow for forward approach....
-
11B-404.3.5 Controls
A level and clear floor or ground space for forward or parallel approach complying with Section 11B-305 should be provided, centered on the operating device....
-
11B-1008.4.3 Play tables
primarily for children 5 years and younger shall not be required to provide knee clearance where the clear floor or ground space required by Section 11B-1008.4.2 is arranged for a parallel approach...
-
806.2.3 Sleeping Areas
The clear floor space shall be positioned for parallel approach to the side of the bed....
-
ADDITIONAL INFORMATION ABOUT THE 2010 STANDARDS
What is the Department's approach going to be to ensuring compliance with the new regulation pertaining to pool lifts?...
-
Doors [4.35.3]
Recommendation: For side approaches, maneuvering is easier for a latch-side approach where doors swing out and a hinge-side is often easier where doors swing in....
-
§382.3 Expected maximum flight duration
time to and from the terminals, based on the scheduled flight time and factors such as (a) wind and other weather conditions forecast; (b) anticipated traffic delays; (c) one instrument approach...
-
1134A.8, Item 1
Vanities and lavatories shall be installed with the centerline of the fixture a minimum of 18 inches (457 mm) horizontally from an adjoining wall or fixture to allow for forward approach...
-
1134A.8, Item 1
Vanities and lavatories shall be installed with the centerline of the fixture a minimum of 18 inches (457 mm) horizontally from an adjoining wall or fixture to allow for forward approach...
-
Ground Level Play Component
A play component that is approached and exited at the ground level....
-
106.5.33 Ground Level Play Component
A play component that is approached and exited at the ground level....
-
Ground-Level Play Components
Ground-Level Play Components Ground-level play components are items that can be approached and exited at ground level....
-
30.1 Q. Would it be acceptable to use removable base cabinets beneath a wall-hung lavatory where a parallel approach is not possible?
A. Yes. The space under and around the cabinet should be finished prior to installation. For example, the tile or other floor finish must extend under the removable base cabinet.
-
QUESTION: WHERE THE TRACK ADJACENT TO A PLATFORM IS NOT SHARED WITH FREIGHT, ARE THERE ANY CIRCUMSTANCES IN WHICH AN APPROACH OTHER THAN LEVEL BOARDING IS ALLOWABLE?
ANSWER: There may be some situations where level boarding is not physically feasible (e.g., where the curvature of the track is too great to make level boarding...
-
Kitchens, Kitchenettes, or Wet Bars [9.2.2(7)]
Kitchens, Kitchenettes, or Wet Bars [9.2.2(7)] Clear floor space for either a forward or a side approach is permitted for cabinets, counters, sinks, and appliances....
-
5. Clear floor space
Clear floor space is needed for a forward approach to the lavatory....
-
GROUND LEVEL PLAY COMPONENT
[DSA-AC] A play component that is approached and exited at the ground level....
-
GROUND LEVEL PLAY COMPONENT
[DSA-AC] A play component that is approached and exited at the ground level....
-
Attachment H
Provide a paper towel dispenser with the controls a maximum height above the finished floor of 48 inches for a forward approach or 54 inches for a side approach and that is accompanied by...
-
5. Bed with clear floor space
Bed with clear floor space for a side approach next to bed....
-
"Path of travel"
The CBC defines "path of travel" as: • "An identifiable accessible route within an existing site, building or facility by means of which a particular area may be approached, entered and...