identify, both objectively and subjectively, the spatial and configurational dimensions of grab-bars that effectively support both independent standing and one- and two-person assisted toilet transfers...
Search Results "Transfer Position"
- Mayer-Rothschild Foundation: Determination of Grab Bar Specifications for Independent and Assisted Transfers in Residential Care Settings
-
1002.5.3 Transfer Entry
1002.5.3 Transfer Entry....
-
1009.5.4 Transfer Steps
Transfer step height shall be 8 inches (205 mm) maximum....
-
Wall Depth and Length: ADA Standard Section 1009.4.3
The depth of the transfer wall shall be 12 inches (305 mm) minimum and 16 inches (405 mm) maximum....
-
11B-1009.4.3 Wall depth and length
The depth of the transfer wall shall be 12 inches (305 mm) minimum and 16 inches (406 mm) maximum....
-
11B-1009.4.3 Wall depth and length
The depth of the transfer wall shall be 12 inches (305 mm) minimum and 16 inches (406 mm) maximum....
-
Seat Heights
Seat Heights: Transfer platforms in play areas need to be between 11 and 18 inches maximum above the ground (ADA-ABA Section 1008.3.1.2)[7]....
-
M305.2.4.2 Non-Circular Cross Section
Transfer supports with non-circular cross sections shall have a cross-section dimension of 2 inches (51 mm) maximum and a perimeter dimension of 4 inches (100 mm) minimum and 4.8 inches...
-
Side Transfer Surface
A transfer surface located within the length of the examination surface that allows patient transfer on two opposing sides of the examination surface....
-
End Transfer Surface
A transfer surface located at one end of an examination surface that allows patient transfer at the end and one adjoining side of the examination surface....
-
1002.5.3 Transfer Entry
Where openings are provided for transfer to amusement ride seats, the openings shall provide clearance for transfer from a wheelchair or mobility aid to the amusement ride seat....
-
1002.5.3 Transfer Entry
Where openings are provided for transfer to amusement ride seats, the openings shall provide clearance for transfer from a wheelchair or mobility aid to the amusement ride seat....
-
1009.5.4 Transfer Steps
Transfer step height shall be 8 inches (205 mm) maximum....
-
11B-243 SHOOTING FACILITIES WITH FIRING POSITIONS
[See subsections ...]
-
11B-1010 SHOOTING FACILITIES WITH FIRING POSITIONS
[See subsections ...]
-
11B-1010 Shooting facilities with firing positions
[See subsections ...]
-
11B-243 Shooting facilities with firing positions.
[See subsections ...]
-
11B-243 Shooting facilities with firing positions
[See subsections ...]
-
11B-1010 Shooting facilities with firing positions
[See subsections ...]
-
703.3.2 Position
Braille shall be positioned below the corresponding text. If text is multi-lined, braille shall be placed below the entire text....
-
M101.2 Application (Section-by-Section Analysis)
Additionally, this provision stated that where the equipment was designed to support more than one patient position, the MDE Standards for each patient position supported would be applied...
-
M301.3.3 Head and Back Support
in a seated position can be adjusted to reclined positions (M301.3.3 and M302.3.3) would require head and back support to be provided throughout the entire range of the incline....
-
Transfer Walls
Transfer Walls A transfer wall is a wall along an accessible route that allows a person to leave a mobility device and transfer onto the wall and then into a pool or spa....
-
Wheelchair Space or Transfer Seat or Transfer Device