Where shooting facilities with firing positions are designed and constructed at a site, at least 5 percent, but no fewer than one, of each type of firing position shall comply with Section...
Search Results "Transfer Position"
Commonly Searched Documents
-
11B-243.1 General
-
11B-243.1 General
Where shooting facilities with firing positions are designed and constructed at a site, at least 5 percent, but no fewer than one, of each type of firing position shall comply with Section...
-
(2) Adjustability: Minimum Low Transfer Height
In addressing what the low transfer height should be, 12 commenters responded to question 14 specifically addressing the proposed minimum low transfer surface height....
-
1009.4.2 Height
The height of the transfer wall shall be 16 inches (405 mm) minimum and 19 inches (485 mm) maximum measured from the deck. Figure 1009.4.2 Transfer Wall Height...
- PlayLSI Tree Stump Transfer Module
-
Ticket transfer. (Section-by-Section Analysis)
Ticket transfer. The Department received many comments asking whether accessible seating has the same transfer rights as general seats....
- Figure 1009.5.2 Clear Deck Space at Transfer Platform – Drawing from the U.S. Access Board
-
11B-1009.4.2 Height
The height of the transfer wall shall be 16 inches (406 mm) minimum and 19 inches (483 mm) maximum measured from the deck. FIGURE 11B-1009.4.2 TRANSFER WALL HEIGHT...
-
1009.4.2 Height
The height of the transfer wall shall be 16 inches (405 mm) minimum and 19 inches (485 mm) maximum measured from the deck. Figure 1009.4.2 Transfer Wall Height...
-
2. Armrests Requirement
In the MDE NPRM, the Access Board required diagnostic equipment used by patients in the seated position to provide armrests (proposed M302.3.2)....
-
1009.5.6 Size
Each transfer step shall have a tread clear depth of 14 inches (355 mm) minimum and 17 inches (430 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum....
-
Frequency: ADA Standard Section 407.4.8.2.3
Section 407.4.8.2.3 covers the current ADA Standards for the frequency of audible elevator car indicators.
-
11B-407.4.8.1.2 Location
Indicators shall be located above the car control panel or above the door.
-
11B-407.4.8.2.3 Frequency
The verbal annunciator shall have a frequency of 300 Hz minimum to 3000 Hz maximum.
-
11B-1009.5.6 Size
Each transfer step shall have a tread clear depth of 14 inches (356 mm) minimum and 17 inches (432 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum....
-
1009.5.6 Size
Each transfer step shall have a tread clear depth of 14 inches (355 mm) minimum and 17 inches (430 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum....
-
407.4.8 Car Position Indicators
Audible and visible car position indicators shall be provided in elevator cars....
-
407.4.8 Car Position Indicators
Audible and visible car position indicators shall be provided in elevator cars....
-
§ 36.304(d)(2)(iii)(K)
(K) Shooting facilities with firing positions, sections 243 and 1010....
-
1002.5.2 Transfer Height
1002.5.2 Transfer Height....
-
4.10.13* Car Position Indicators
In elevator cars, a visual car position indicator shall be provided above the car control panel or over the door to show the position of the elevator in the hoistway....
-
4.10.13* CAR POSITION INDICATORS
In elevator cars, a visual car position indicator shall be provided above the car control panel or over the door to show the position of the elevator in the hoistway....
-
6. Minimum (Low) Height Standard for Transfer Surfaces
Minimum (Low) Height Standard for Transfer Surfaces As indicated in Section 5.1.1, the MDE Advisory Committee recommends that equipment with transfer surfaces be height adjustable in...
-
1009.5.3 Height
The height of the transfer platform shall comply with 1009.4.2....