Extensions shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent stair flight....
Search Results "Kitchen Work Surface"
Commonly Searched Documents
-
505.10.2 Top Extension at Stairs
-
R305.2 Placement
The placement of detectable warning surfaces shall comply with R305.2. Advisory R305.2 Placement. Some detectable warning products require a concrete border for proper installation....
-
Seating [4.32.2] and Knee Clearance [4.32.3]
The over-the-surface reach is limited to 25 inches if at least this much space is available below for knees and toes; (the forward seated reach may not extend beyond the toes)....
-
1018.10 Dune Crossings
The curbs or barriers are required to prevent the passage of a 2 inch diameter sphere, where any portion of the sphere is within 2 inches of the crossing surface....
-
11B-1009.5.2 Transfer space
A transfer space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
§ 38.119(b)
doorways of cars not operating at lighted station platforms shall have outside lights which, when the door is open, provide at least 1 foot-candle of illumination on the station platform surface...
-
§ 38.81(c)
(c) The doorways of vehicles not operating at lighted station platforms shall have outside lights which provide at least 1 foot-candle of illumination on the station platform or street surface...
-
11B-407.4.6.2.1 Size and shape
Buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in their smallest dimension and be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding surface...
-
11B-1009.5.2 Transfer space
A transfer space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
Robert Dupuy, IALD, LC. Problems and Solutions
Historic Basis for Lighting Criteria I think, first off, a little-known fact about the lighting levels that all of us use daily to do our work and that we also find in lighting codes...
-
4. Organization of Technical Criteria
For example, X-ray equipment that is designed for use in a standing position for certain procedures would have to meet the technical criteria for slip resistant standing surface and standing...
-
Fulton County - ADA Administrator
Organizes, prioritizes, and assigns work: prioritizes and schedules work activities in order to meet objectives; ensures that subordinates have the proper resources needed to complete the...
-
Record Retention
I work at a Public Housing Authority as the ADA Coordinator. I have been ask to supply the record retention schedule for resident and employee ADA requests. ...
-
218 and 810 Transportation Facilities
Detectable warnings provide a distinctively textured surface of truncated domes....
-
QUESTION: WHAT CONSTITUTES AN ALTERATION TO A PLATFORM FOR PURPOSES OF TRIGGERING THE APPLICATION OF SECTION 37.42 REQUIREMENTS?
For example, if the platform height relative to the top of rail is raised, if the old surface is removed and/or a new surface put down, or if there is a reconstruction of or structural change...
-
Scoping [4.1.2(1), 4.1.3(1)] and Location [4.3.2]
Clear width, surface texture, running and cross slope, and the treatment of changes in level help determine the usability of walking surfaces by people with mobility impairments....
-
1016.5 Obstacles
The vertical alignment of joints in concrete, asphalt, or board surfaces on outdoor recreation access routes can be obstacles....
-
Purpose of the project
For instance, when this project began, tolerances for the measurement of the slope, flatness, and smoothness of exterior walking and rolling surfaces in concrete, asphalt, unit masonry,...
-
Clearance Around Base (M301.4.2 and M302.4.2)
M302.4.2 would require the base of the equipment to provide a clearance 6 inches high minimum measured from the floor and 36 inches deep minimum measured from the edge of the examination surface...
-
§ 38.159(b)(13) Handrails
The handrail shall have a cross-sectional diameter between 11/4 inches (32 mm) and 11/2 inches (38 mm) or shall provide an equivalent grasping surface, and have eased edges with corner radii...
-
§ 38.29(b)
Handrails shall have a cross-sectional diameter between 11/4 inches and 11/2 inches or shall provide an equivalent grasping surface, and have eased edges with corner radii of not less than...
-
2. There are a limited number of other employees available to perform the function, or among whom the function can be distributed
The heavy work flow during peak periods may make performance of each function essential, and limit an employer's flexibility to reassign a particular function....
-
11B-108 Maintenance of accessible features
A public accommodation shall maintain in operable working condition those features of facilities and equipment that are required to be accessible to and useable by persons with disabilities...
-
Comments on specific provisions of proposed ADAAG (Preamble, Section-by-Section Analysis)
Those areas that elicited the heaviest response included assistive listening systems, automated teller machines, work areas, parking, areas of refuge, telephones (scoping for TDD’s and volume...