Function keys shall contrast visually from background surfaces. Characters and symbols on key surfaces shall contrast visually from key surfaces....
Search Results "Side Transfer Surface"
Commonly Searched Documents
-
707.6.3.1 Contrast
-
A4.30.8 Illumination Levels
Illumination levels on the sign surface shall be in the 100 to 300 lux range (10 to 30 footcandles) and shall be uniform over the sign surface....
-
Thresholds at Doorways
The 1991 Standards and the 2010 Standards require raised thresholds that exceed ¼ inch in height to be beveled on each side with a slope not steeper than 1:2....
-
410.6 Doors and Gates
Side doors and gates shall provide a clear width 42 inches (1065 mm) minimum....
-
11B-503.3.3 Marking
The area within the borderlines shall be marked with hatched lines a maximum of 36 inches (914 mm) on center in a color contrasting with that of the aisle surface....
-
Summary of Results
Therefore, the results can be addressed in terms of a general trend in types of surface materials used....
- DORMA 8000 Series Exit Device
-
2.2.6 Door Use
Trials in both directions were performed (i.e. from push and pull sides) using a forward approach. Each door presented different types of challenges to WhMD users....
-
11B-408.4.6 Car controls
Control panels shall be centered on a side wall....
-
11B-802.4.1 Armrests
Where armrests are provided on the seating in the immediate area, folding or retractable armrests shall be provided on the aisle side of the seat....
-
802.4.1 Armrests
Where armrests are provided on the seating in the immediate area, folding or retractable armrests shall be provided on the aisle side of the seat....
-
1013.2 Clear Ground Space
Clear ground space complying with 1013.2 shall be provided on all usable sides of tent pads and tent platforms....
-
409.4.6.2 Location
Control panels shall be on a side wall, 12 inches (305 mm) minimum from any adjacent wall....
-
802.4.1 Armrests
Where armrests are provided on the seating in the immediate area, folding or retractable armrests shall be provided on the aisle side of the seat....
-
H18
Is the centerline of the toilet 18 inches from the adjacent side wall? [ADA Standards § 4.16.2; 4.17.3] Yes No...
-
M16
Is the centerline of the toilet 18 inches from the adjacent side wall? [ADA Standards §§ 4.16.2; 4.17.3] Yes No...
-
1002.4.6 Approach
One side of the wheelchair space shall adjoin an accessible route when in the load and unload position....
-
4.15.4 Controls
Unit controls shall be front mounted or side mounted near the front edge....
-
4.15.4 CONTROLS
Unit controls shall be front mounted or side mounted near the front edge....
-
1013.2 Clear Ground Space
Clear ground space complying with 1013.2 shall be provided on all usable sides of tent pads and tent platforms....
-
11B-409.4.6.2 Location
Control panels shall be on a side wall, 12 inches (305 mm) minimum from any adjacent wall....
-
11B-802.4.1 Armrests
Where armrests are provided on the seating in the immediate area, folding or retractable armrests shall be provided on the aisle side of the seat....
-
11B-408.4.6 Car controls
Control panels shall be centered on a side wall....
-
11B-802.4.1 Armrests
Where armrests are provided on the seating in the immediate area, folding or retractable armrests shall be provided on the aisle side of the seat....