permitted to protrude a distance of 6 inches (152 mm) maximum along the front of the wheelchair space, where located 9 inches (229 mm) minimum and 27 inches (686 mm) maximum above the floor...
Search Results "NFSI: National Floor Safety Institute"
-
11B-1002.4.4.3 Permitted protrusions in wheelchair spaces
-
1002.4.4.3 Permitted Protrusions in Wheelchair Spaces
permitted to protrude a distance of 6 inches (150 mm) maximum along the front of the wheelchair space, where located 9 inches (230 mm) minimum and 27 inches (685 mm) maximum above the floor...
-
407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with tactile symbols as shown in Table 407.4.7.1.3....
-
609.4 Position of Grab Bars
Grab bars shall be installed in a horizontal position, 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
(c) Thresholds at patio, deck or balcony doors
The final Guidelines provide that exterior deck, patio, or balcony surfaces should be no more than 1/2 inch below the floor level of the interior of the dwelling unit, unless they are constructed...
-
7b.
[ADA Stds 4.13.9] Yes _____ No _____ A clear floor space on the latch side of the door (pull side) allows a person using a wheelchair or scooter to pull the door open and then...
-
4.10.13* Car Position Indicators
As the car passes or stops at a floor served by the elevators, the corresponding numerals shall illuminate, and an audible signal shall sound....
-
Raised and Braille Characters on Hoistway Entrances [4.10.5]
Raised and Braille floor designations are required on both jambs, with the centerline 60 inches from the finished floor. Raised characters must be 2 inches high....
-
4.1.3(10)(a)
(a) Where only one drinking fountain is provided on a floor there shall be a drinking fountain which is accessible to individuals who use wheelchairs in accordance with 4.15 and one accessible...
-
609.4 Position of Grab Bars
Grab bars shall be installed in a horizontal position, 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
4.10.13* CAR POSITION INDICATORS
As the car passes or stops at a floor served by the elevators, the corresponding numerals shall illuminate, and an audible signal shall sound....
-
11B-405.9.2 Curb or barrier
mm) high minimum, or barrier shall be provided that prevents the passage of a 4 inch (102 mm) diameter sphere, where any portion of the sphere is within 4 inches (102 mm) of the finish floor...
-
§ 38.23(b)(7) Platform gaps
When the platform is at vehicle floor height with the inner barrier (if applicable) down or retracted, gaps between the forward lift platform edge and the vehicle floor shall not exceed...
-
11B-405.9.2 Curb or barrier
A curb or barrier shall be provided that prevents the passage of a 4-inch (102 mm) diameter sphere, where any portion of the sphere is within 4 inches (102 mm) of the finish floor or ground...
-
Scoping Requirement for Alarms
ensuring that such alarm systems are accessible to people who are deaf or hard of hearing, but no information was received on appropriate technical specifications for guidelines that are national...
-
SUMMARY
For more information, see resource material developed as part of the National Cooperative Highway Research Program Project 3-62: Guidelines for Accessible Pedestrian Signals at http://www.walkinginfo.org...
-
Executive Order 13132: Federalism
The Americans with Disabilities Act was enacted “to provide a clear and comprehensive national mandate for the elimination of discrimination against individuals with disabilities.” 42 U.S.C...
-
RESPONSE AND RECOVERY OPERATIONS
Voluntary Organizations Active in Disaster (VOAD) National Voluntary Organizations Active in Disaster (NVOAD) is a nonprofit membership-based organization that builds resiliency in communities...
-
E205.3 Agency Official Communication
EXCEPTION: Records maintained by the National Archives and Records Administration (NARA) pursuant to federal recordkeeping statutes shall not be required to conform to the 508 Standards...
-
Kurt Knight: Development of VA Standards
Compliance with national codes is a given. We comply with national codes. We have a set of VA criteria standards that are in excess of the codes....
-
May employers subject employees to periodic alcohol testing?
In determining whether to subject such an employee to periodic alcohol testing, the employer should consider the safety risks associated with the position the employee holds, the consequences...
-
Revolving Doors or Turnstiles
people with disabilities, certain questions remain about the appropriate maximum speed, minimum diameter, compartment size, width and configuration of openings, break out openings, and safety...
-
382.53 What information must carriers give individuals with a vision or hearing impairment at airports?
This requirement applies to a wide variety of information, concerning such subjects as flight safety, ticketing, flight check-in, flight delays or cancellations, schedule changes, boarding...
-
§382.117(f)
., whether the animal is too large or heavy to be accommodated in the cabin, whether the animal would pose a direct threat to the health or safety of others, whether it would cause a significant...