Shelves shall be located 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor. [ECTCR UFAS 4.25.3, Fig. 38]...
Search Results "Feasibility (Technical, Infeasible, Structural, Maximum Extent)"
-
603.4 Coat Hooks and Shelves
-
11B-703.2.8 Line spacing
Spacing between the baselines of separate lines of raised characters within a message shall be 135 percent minimum and 170 percent maximum of the raised character height. [S.H. ...
-
308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220 mm) maximum and the low forward reach shall be 15 inches (380 mm) minimum above the finish floor or...
-
602.5 Spout Location
The spout shall be located 15 inches (380 mm) minimum from the vertical support and 5 inches (125 mm) maximum from the front edge of the unit, including bumpers....
-
11B-1009.6.1 Pool stairs
Exception: Pool step riser heights shall not be required to be 4 inches (102 mm) high minimum and 7 inches (178 mm) high maximum provided that riser heights are uniform....
-
B1. Slope
Is a relatively level (1:50 or 2% maximum slope in all directions) access aisle provided adjacent and parallel to the side of the vehicle pull-up area?...
-
Clear Width [4.8.3]
A maximum clear width is not specified....
-
11B-1009.6.1 Pool stairs
Exception: Pool step riser heights shall not be required to be 4 inches (102 mm) high minimum and 7 inches (178 mm) high maximum provided that riser heights are uniform....
-
11B-1008.2.5.3.1 Handrail gripping surfaces
Handrail gripping surfaces with a circular cross section shall have an outside diameter of 0.95 inch (24 mm) minimum and 1.55 inches (39 mm) maximum....
-
1009.6.1 Pool Stairs
EXCEPTION: Pool step riser heights shall not be required to be 4 inches (100 mm) high minimum and 7 inches (180 mm) high maximum provided that riser heights are uniform....
-
602.5 Spout Location
The spout shall be located 15 inches (380 mm) minimum from the vertical support and 5 inches (125 mm) maximum from the front edge of the unit, including bumpers....
-
Legislation
1/2" Obstacle Height 1/4" No slope required 1/4"-1/2" Beveled with Maximum 1:2 slope...
-
Regarded as having a disability
. § 104.3(j)(2)(iv). 30 Department of Justice: ADA, Title II Technical Assistance Manual, II-2.6000, www.ada.gov/taman2.html#II-2.6000; 34 C.F.R. pt. 104, App....
- Inpro Corporation JointMaster® 787 Series Floor Expansion Joint Covers
- EZ-ACCESS Transitions® Modular Entry Ramp
- Haws AXION® MSR Barrier-Free Recessed Eye/Face Wash 7655WCC
- ADA Solutions, Inc. Surface Applied Truncated Dome Detectable Warning Systems
- Inpro Corporation ENDURANT® Floor-to-Ceiling Mounted Partitions
- Lift-U® Fold-Out Rising Floor Ramp
-
Limited-Use/Limited-Application Elevators, Destination-Oriented Elevators and Private Residence Elevators
If a facility is exempt from the scoping requirement, but nonetheless installs an elevator, the 1991 Standards require the elevator to comply with the technical requirements for elevators...
-
INTRODUCTION
standard-setting agencies; the Department of Defense (DoD) prescribes standards for DoD installations; the Department of Housing and Urban Development (HUD) prescribes standards for residential structures...
-
207 Accessible Means of Egress
All technical criteria for accessible means of egress (409), including areas of refuge (410) have been removed in the final rule....
-
Existing play areas. (Section-by-Section Analysis)
To meet program accessibility requirements where structural changes are necessary, public entities have been required to apply the general new construction and alteration standards to the...
-
11B-406.3.2 Turning space
The slope of the turning space in all directions shall be 1:48 maximum. FIGURE 11B-406.3.2 ‡‡ PARALLEL CURB RAMPS...