Spacing between the baselines of separate lines of characters within a message shall be 135 percent minimum and 170 percent maximum of the character height.
Search Results "Tactile Map"
Commonly Searched Documents
-
703.5.9 Line Spacing
-
703.5.9 Line Spacing
703.5.9 Line Spacing. Spacing between the baselines of separate lines of characters within a message shall be 135 percent minimum and 170 percent maximum of the character height.
-
11B-703.5.9 Line spacing
11B-703.5.9 Line spacing. Spacing between the baselines of separate lines of characters within a message shall be 135 percent minimum and 170 percent maximum of the character height.
-
11B-703.5.9 Line spacing
Spacing between the baselines of separate lines of characters within a message shall be 135 percent minimum and 170 percent maximum of the character height.
-
§27.71(k)
(k) Shared-use automated airport kiosks provided in accordance with paragraph (j) of this section must conform to the following technical accessibility standards with respect to...
-
§ 27.71(k)
(k) Shared-use automated airport kiosks provided in accordance with paragraph (j) of this section must conform to the following technical accessibility standards with respect to...
-
Can doors swing into required clear floor or ground space?
where wheelchair space beyond the door swing is provided) (603.2.3) clear floor space required at benches in saunas and steam rooms (612.2) clear floor space required at tactile...
-
703.5 Visual Characters
Visual characters shall comply with 703.5. EXCEPTION: Where visual characters comply with 703.2 and are accompanied by braille complying with 703.3, they shall not be required to...
-
11B-703.5 Visual characters
Visual characters shall comply with Section 11B-703.5. Exception: Where visual characters comply with Section 11B-703.2 _|Signs; Raised Characters|_ and are accompanied by Braille...
-
703.5 Visual Characters
Visual characters shall comply with 703.5. EXCEPTION: Where visual characters comply with 703.2 and are accompanied by braille complying with 703.3, they shall not be required to...
-
703.5 Visual Characters
703.5 Visual Characters. Visual characters shall comply with 703.5. EXCEPTION: Where visual characters comply with 703.2 and are accompanied by braille complying with 703.3, they...
-
11B-703.5 Visual characters
11B-703.5 Visual characters. Visual characters shall comply with Section 11B-703.5. Exception: Where visual characters comply with Section 11B-703.2 _|Signs; Raised Characters|_...
-
11B-220.2 Point-of-sale devices
Where point-of-sale devices are provided, all devices at each location shall comply with Sections 11B-707.3 _|Operable Parts|_, 11B-707.7.2 _|Characters|_, and 11B-707.9...
-
11B-703.5 Visual characters
Visual characters shall comply with Section 11B-703.5. Exception: Where visual characters comply with Section 11B-703.2 and are accompanied by Braille complying with Section...
-
11B-220.2 Point-of-sale devices
Where point-of-sale devices are provided, all devices at each location shall comply with Sections 11B-707.3, 11B-707.7.2, and 11B-707.9. Where point-of-sale devices are provided at...
-
ViewPlus Technologies VP Tactile Graphics Video
Requires the Registered User plan or above. Login!
- ADA Solutions, Inc. Radius Tactile Detectable Warning Surface
- ADA Solutions, Inc. Cast in Place Tactile Surface
-
11B-703.5.6 Height from finish floor or ground
Visual characters shall be 40 inches (1016 mm) minimum above the finish floor or ground. Exceptions: 1. Visual characters indicating elevator car controls shall not be...
-
Registered Accessibility Specialist (RAS) Bulletin RAS 2014-04 Signs - Exit Doors
RAS 2014-04 Signs - Exit Doors Effective Date: July 7, 2014 2012 TAS Reference: 216.4.1 In accordance with TAS 216.4.1, doors at exit passageways, exit discharges,...
-
11B-703.5.6 Height from finish floor or ground
11B-703.5.6 Height from finish floor or ground. Visual characters shall be 40 inches (1016 mm) minimum above the finish floor or ground. Exceptions: 1. Visual characters...
-
11B-703.5.6 Height from finish floor or ground
Visual characters shall be 40 inches (1016 mm) minimum above the finish floor or ground. Exceptions: Visual characters indicating elevator car controls shall not be required...
-
A4.29.3 TACTILE WARNINGS ON DOORS TO HAZARDOUS AREAS
Tactile signals for hand reception are useful if it is certain that the signals will be touched....