Elevator doors shall be provided with a reopening device complying with Section 11B-407.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed...
Search Results "Open Doors Organization"
-
11B-407.3.3 Reopening device
- Norton Surface Mounted Medium Duty 8000 Series Door Closer
-
1132A.3 Width and height of interior doors and secondary exterior doors
Swinging doors shall provide a net clear opening width of not less than 32 inches (813 mm), measured with the door or doors positioned at an angle of 90 degrees from the closed position....
-
404.3.4 Doors in Series and Gates in Series
404.3.4 Doors in Series and Gates in Series. Doors in series and gates in series shall comply with 404.2.6....
- Allegion Falcon SC90 Series Surface Mounted Door Control
- Allegion Falcon SC60 Series Surface Mounted Door Closer
-
Location: ADA Standard Section 409.3.2
Section 409.3.2 covers the current ADA Standards for the location of private residence elevator doors.
-
Openings [1017.6]
Openings are gaps in the surface of a trail....
-
Doors
Doors: a. Main Lobby restroom: provide a restroom vestibule door with at least 18" of maneuvering clearance on the latch side of the door. See Standards § 4.13.6....
- Corbin Russwin Inc. DC62900 Series Electromechanical Closer-Holder
-
410.6 Doors and Gates
Platform lifts shall have low-energy power-operated doors or gates complying with 404.3. Doors shall remain open for 20 seconds minimum....
-
Openings [1016.6]
Openings are gaps in the surface of an ORAR....
-
Door and Signal Timing for Hall Calls [4.10.7], Door Delay for Car Calls [4.10.8]
Timing, based on the distance between the farthest call button and the elevator door, begins with visible and audible signaling of car arrival....
-
410.6 Doors and Gates
Platform lifts shall have low-energy power-operated doors or gates complying with 404.3. Doors shall remain open for 20 seconds minimum....
-
410.6 Doors and Gates
410.6 Doors and Gates. Platform lifts shall have low-energy power-operated doors or gates complying with 404.3. Doors shall remain open for 20 seconds minimum....
-
404.2.7 Door and Gate Hardware
Handles, pulls, latches, locks, and other operable parts on doors and gates shall comply with 309.4....
-
11B-404.2.4.1 Swinging doors and gates
Swinging doors and gates shall have maneuvering clearances complying with Table 11B-404.2.4.1....
-
11B-404.2.4.1 Swinging doors and gates
Swinging doors and gates shall have maneuvering clearances complying with Table 11B-404.2.4.1....
-
4.9.2 TREADS AND RISERS
Open risers are not permitted on accessible routes....
- Allegion LCN 3130 Series Overhead Concealed Door Control
- Allegion LCN 2010 Series Overhead Concealed Door Control
- ADAEZ Pro Plus Automatic Door Opener Installing Door Operator and Door Arm Video
-
404.3.4 Doors in Series and Gates in Series
Doors in series and gates in series shall comply with 404.2.6....
-
404.3.4 Doors in Series and Gates in Series
Doors in series and gates in series shall comply with 404.2.6....