Search Results "Means of Egress Signage"
Commonly Searched Documents
- 
    
  
  Excerpts from 2001 INTERNATIONAL BUILDING CODE®
  
- 
    
  
  1007.7.1 Level of exit discharge
  1007.7.1 Level of exit discharge. Where the exit discharge does not include an accessible route from an exit located on a level of exit discharge to a public way, an exterior area of... 
- 
    
  
  4.1.6(1)(g)
  (g) In alterations, the requirements of 4.1.3(9), 4.3.10 and 4.3.11 do not apply. 
- 
    
  
  Requirements for Platform Lifts
  Platform Lift Clear Floor Space and Doors/ Gates 
- 
    
  
  1009.8.1.1 Visible communication method
  [DSA-AC and HCD 1-AC] A button complying with Section 1138A.4 or Sections 11B-205 and 11B-309 _|Operable Parts|_ in the area of refuge shall activate both a light in the area of... 
- 
    
  
  1009.6.5 Two-way communication
  Areas of refuge shall be provided with a two-way communication system complying with Sections 1009.8.1 and 1009.8.2. 
- 
    
  
  1009.6.5 Two-way communication
  Areas of refuge shall be provided with a two-way communication system complying with Sections 1009.8.1 and 1009.8.2. 
- 
    
  
  1009.8.1.1 Visible communication method
  [DSA-AC and HCD 1-AC] A button complying with Section 1138A.4 or Sections 11B-205 and 11B-309 in the area of refuge shall activate both a light in the area of refuge indicating that... 
- 
    
  
  4.1.3(16) Building Signage
  (16) Building Signage:... 
- 
    
  
  Speech Disabilities
  The only “standard” building egress systems that may require a person to have the ability to speak in order to evacuate a building are the emergency phone systems in areas of refuge, elevators... 
- 
    
  
  1003.2.13.7.2 Exterior exit stairway
  Exterior exit stairways that are part of the means of egress for the exterior area for assisted rescue shall provide a clear width of 48 inches (1219 mm) between handrails.... 
- 
    
  
  11B-404.3.2 Maneuvering clearance
  Clearances at automatic doors and gates without standby power and serving an accessible means of egress shall comply with Section 11B-404.2.4.... 
- 
    
  
  11B-404.3.2 Maneuvering clearance
  Clearances at automatic doors and gates without standby power and serving an accessible means of egress shall comply with Section 11B-404.2.4.... 
- 
    
  
  11B-404.3.2 Maneuvering clearance
  Clearances at automatic doors and gates without standby power and serving an accessible means of egress shall comply with Section 11B-404.2.4.... 
- 
    
  
  1009.8 Two-way communication
  Two-way communication systems are not required at the landings serving only service elevators that are not designated as part of the accessible means of egress or serve as part of the required... 
- 
    
  
  Non-Tactile Signage
  Non-Tactile Signage The legibility of printed characters is a function of the viewing distance, character height and proportion, font, and the color contrast between character and background... 
- Innerface Parallel Interior Signage
- 
    
  
  1009.8 Two-way communication
  Two-way communication systems are not required at the landings serving only service elevators that are not designated as part of the accessible means of egress or serve as part of the required... 
- 
    
  
  SIGNAGE
  SIGNAGE. [DSA-AC] Displayed verbal, symbolic, tactile, and/or pictorial information.... 
- 
    
  
  Symbols of Accessibility: ADA Standard Section 703.7
  Symbols of accessibility shall comply with 703.7. 
- TownSteel ED6700 Narrow Stile Concealed Vertical Panic Device
- TownSteel ED1300 Grade 1 Concealed Vertical Rod Panic Device
- 
    
  
  Stairways [ADA Standards §210, §504]
  Stairways [ADA Standards §210, §504] Stairways and handrails that are part of a means of egress are addressed by the IBC (§1009 (2003), §1003.3.3 (2000)).... 
- 
    
  
  SIGNAGE
  [See subsections ...] 