Section 406.4 covers the current ADA Standards for curb ramp landings.
Search Results "Flared Side"
Commonly Searched Documents
-
Landings: ADA Standard Section 406.4
- Bradley Security Grab Bars SA70 Series
-
Figure M3: Overview of M302 Diagnostic Equipment for Use by a Patient in a Seated Position
[See subsections ...]
-
M305.4 Leg Supports
Leg supports shall provide a method of supporting, positioning, and securing the patient’s legs.
-
M301.2 Transfer Surface
A transfer surface shall be provided and shall comply with M301.2.
-
5.2.1 Transfer Surface Size Recommendations for M301
5.2.1 Transfer Surface Size Recommendations for M301 Description: The transfer surface is the part of the diagnostic equipment onto which patients who use mobility devices or aids...
-
5.2.1 Transfer Surface Size
5.2.1 Transfer Surface Size
-
5.2 Transfer Surface Size Recommendations
5.2 Transfer Surface Size Recommendations
-
M301.2.2 Size
The transfer surface shall be 30 inches (760 mm) wide minimum and 15 inches (381mm) deep minimum. Advisory M301.2.2 Size. The size requirements in this section apply only to the...
-
M301.2 Transfer Surface
A transfer surface shall be provided and shall comply with M301.2.
-
M301.2.1 Adjustability (Section-by-Section Analysis)
The MDE NPRM proposed a transfer surface height range for diagnostic equipment used by patients in the supine, prone, or side-lying position of 17 inches minimum and 19 inches maximum....
- UpScale by Medical Accessibility - Adjustable Height Exam Table with Built-in Scale
- Bobrick 48" Straight Grab Bar B-5806 x 48
- Bobrick 48" Straight Grab Bar B-6806 x 48
-
5.4.7 Transfer Support Gripping Surface Clearance Recommendation for M301 and M302
is considering whether 1½ inches minimum clearance around the gripping surface would be appropriate for transfer supports on diagnostic equipment used by patients in a supine, prone, or side-lying...
-
M301.3.2 Leg Supports
Where stirrups are provided, leg supports shall also be provided and shall comply with M305.4.
-
M305.4 Leg Supports (Section-by-Section Analysis)
As discussed above in Section V.C.3.b (Section-by-Section Analysis – M301.3.2) and Section V.C.7.b (Section-by-Section Analysis – M302.3.2), the technical requirements for leg...
-
M301.2.1, M302.2.1 Transfer Height
M301.2.1, M302.2.1 Transfer Height Proposed requirement: The height of the transfer surface during patient transfer shall be 17 inches (430 mm) minimum and 19 inches (485 mm)...
-
iv. Lifts
iv. Lifts Medical providers may need lifts to transfer some patients with mobility disabilities safely to examination or treatment tables or chairs or to gurneys or hospital beds....
-
M301.3.2 Stirrups
Where stirrups are provided, they shall provide a method of supporting, positioning, and securing the patient’s legs.
- Georgia-Pacific Compact® Side-By-Side Double Roll Bathroom Tissue Dispenser 56798
-
Side guard protocol
Side guard protocol: From initial setup, two side guards adjusted 6” (15.2 cm) higher than the subject’s WMD seat were attached, and subjects were asked to perform a level height transfer...
-
Regulatory Impact Analysis.
proposed requirements for each of the following eight existing elements will exceed monetized benefits by more than $100 million when using the 1991 Standards as the comparative baseline: Side...