Means of egress shall comply with section 1003.2.13 of the International Building Code (2000 edition and 2001 Supplement) or section 1007 of the International Building Code (2003 edition...
Search Results "IBC: International Building Code"
-
207.1 General
-
207.2 Platform Lifts
Standby power shall be provided for platform lifts permitted by section 1003.2.13.4 of the International Building Code (2000 edition and 2001 Supplement) or section 1007.5 of the International...
-
216.4.2 Areas of Refuge
Signs required by section 1003.2.13.5.4 of the International Building Code (2000 edition) or section 1007.6.4 of the International Building Code (2003 edition) (incorporated by reference...
-
216.4.3 Directional Signs
Signs required by section 1003.2.13.6 of the International Building Code (2000 edition) or section 1007.7 of the International Building Code (2003 edition) (incorporated by reference, see...
-
Alterations to stairs. (Section-by-Section Analysis)
The International Building Code (IBC), which is a private sector model construction code, contains a similar provision, and most jurisdictions enforce a version of the IBC as their building...
-
Railings—Guardrails, Handrails, and Safety
For safety, the International Building Code (IBC), http://www.iccsafe.org, section 1003.2.12 contains requirements for guardrail height and the spacing of rails where there is a drop off...
-
§100.205(e)(2)(vi) 2006 International Building Code
(vi) 2006 International Building Code; published by ICC, January 2006, with the January 31, 2007, erratum to correct the text missing from Section 1107.7.5, if adopted without modification...
-
F216.4.2 Areas of Refuge
Signs required by section 1003.2.13.5.4 of the International Building Code (2000 edition) or section 1007.6.4 of the International Building Code (2003 edition) (incorporated by reference...
-
F216.4.3 Directional Signs
Signs required by section 1003.2.13.6 of the International Building Code (2000 edition) or section 1007.7 of the International Building Code (2003 edition) (incorporated by reference, see...
-
207 Accessible Means of Egress
-
General
Section 207.1 of the 2010 Standards reference the International Building Code (IBC) for scoping and technical requirements for accessible means of egress....
-
Standby Power for Platform Lifts
Standby Power for Platform Lifts. The 2010 Standards at section 207.2 require standby power to be provided for platform lifts that are permitted to serve as part of an accessible...
-
Accessible Fishing Piers and Platforms
Two commenters stated that allowing a 42-inch guard or railing height for facilities covered by another building code would be difficult to enforce....
-
Accessible Means of Egress
This guide explains requirements in the ADA Standards and referenced sections of the International Building Code (IBC) and was developed in cooperation with the International Code...
-
Required Compliance with the IBC [§207]
Required Compliance with the IBC [§207] Accessible means of egress must be provided according to the International Building Code (IBC)....
-
ICC/IBC: ADA Standard Section 105.2.4
Section 105.2.4 of the ADA Standards cover references to the International Code Council (ICC) and the International Building Code (IBC)....
-
Required Means of Egress [IBC §1007.1 (2003), §1003.2.13 (2000)]
The IBC requires at least two means of egress from all spaces and buildings with few exceptions....
-
Exit Stairway Enclosures [IBC §1007.3 and 1019 (2003), §1003.2.13.2 and 1005.3.2 (2000)]
The IBC contains requirements for exit stairway enclosures that address fire-resistance and smoke protection, stairways and handrails, signs, and other features. The ADA...
-
Stairways [ADA Standards §210, §504]
Stairways [ADA Standards §210, §504] Stairways and handrails that are part of a means of egress are addressed by the IBC (§1009 (2003), §1003.3.3 (2000)). In addition, interior...
-
Handrails [ADA Standards §504.6, §505]
Handrails [ADA Standards §504.6, §505] Specifications in the ADA Standards for handrail surfaces and clearances facilitate a power grip along the handrail length. Handrails can...
-
Areas of Refuge [IBC §1007.6 (2003), §1003.2.13.5 (2000)]
Areas of refuge are fire-resistance rated and smoke protected areas where those unable to use stairs can register a call for evacuation assistance and await instructions or...
-
Horizontal Exits [IBC §1021 (2003), §1005.3.5 (2000)]
A horizontal exit compartmentalizes a building allowing occupants to exit the area containing the origin of a fire into another portion of the building that is protected by fire-resistance-rated...
-
Elevators with Standby Power [IBC §1007.4 (2003), §1003.2.13.3 (2000)]
In buildings with four or more stories above or below the level of exit discharge, at least one accessible means of egress must be an elevator with standby power and emergency signaling...
-
Where can one get further information or technical assistance on the IBC, including its requirements for means of egress?
Technical assistance on the IBC is available from the International Code Council (ICC) at (888) ICC-SAFE (422-7233) or by email at CareCenter@iccsafe.org . ...