In a wheelchair accessible compartment with an in-swinging door, a minimum 60 inches (1524 mm) wide by 36 inches (914 mm) deep maneuvering space shall be provided in front of the clearance...
Search Results "Compartment Door"
-
11B-604.8.1.1.1 Maneuvering space with in-swinging door
-
11B-604.8.1.1.1 Maneuvering space with in-swinging door
In a wheelchair accessible compartment with an in-swinging door, a minimum 60 inches (1524 mm) wide by 36 inches (914 mm) deep maneuvering space shall be provided in front of the clearance...
-
Door and Gate Opening Force: ADA Standard Section 404.2.9
Section 404.2.9 covers the current ADA Standards for door and gate opening force.
-
Elevator Door Requirements: ADA Standard Section 407.3
Section 407.3 covers the current ADA Standards for elevator door requirements.
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
In a wheelchair accessible compartment with a door located in the front wall or partition (facing the water closet), either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide...
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
In a wheelchair accessible compartment with a door located in the front wall or partition (facing the water closet), either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide...
-
Toilet Compartment Access
If you look at 604.8.1.2 Doors, it says, "Toilet compartment doors, including door hardware, shall comply with 404 except that if the approach is to the latch side of the compartment...
-
4.17.5* Doors
Toilet stall doors, including door hardware, shall comply with 4.13....
-
11B-213.3.1 Toilet compartments
Where toilet compartments are provided, at least one toilet compartment shall comply with 604.8.1....
-
11B-213.3.1 Toilet compartments
Where toilet compartments are provided, at least one toilet compartment shall comply with 604.8.1....
-
4.17.5* DOORS
Toilet stall doors shall comply with 4.13....
-
Toilet Compartment Access
If the door and access were from the opposite side, although not as accessible I believe it is also §404 compliant because a self-closing door is not the same as a door with a closer? ...
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
In a wheelchair accessible compartment with a door located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep...
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
In a wheelchair accessible compartment with a door located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep...
-
H. Stall Door
If the accessible toilet is in a stall, is the stall door positioned diagonally opposite, not directly in front of, the toilet so persons who use wheelchairs may pull fully into the stall...
-
Door Closers and Gate Closers: ADA Standard Section 404.2.8.1
Section 404.2.8.1 covers the current ADA Standards for the closing speed of door closers and gate closers.
-
Toilet Compartments: ADA Standard Section 213.3.1
Section 213.3.1 covers scoping requirements in the current ADA Standards for toilet compartments.
-
Error/Omission: Adequate maneuvering clearance is not provided at doors, including doors to accessible toilet stalls.
Error/Omission: Adequate maneuvering clearance is not provided at doors, including doors to accessible toilet stalls....
-
11B-213.3.1.1 Toilet compartments
Where toilet compartments are provided, at least five percent of the toilet compartments, or five percent of the combination of toilet compartments and urinals, but no fewer than one toilet...
-
11B-213.3.1.1 Toilet compartments
Where toilet compartments are provided, at least five percent of the toilet compartments, or five percent of the combination of toilet compartments and urinals, but no fewer than one toilet...
-
11B-604.8 Toilet compartments
Wheelchair accessible toilet compartments shall meet the requirements of Sections 11B-604.8.1 and 11B-604.8.3....