The width of the level area on the side to which the door swings shall extend 18 inches (457 mm) past the strike edge for all doors....
Search Results "Swing"
-
1132A.5.2 Strike edge maneuvering space at doors
-
604.8.2.2 Doors
Toilet compartment doors shall not swing into the minimum required compartment area....
-
604.8.2.2 Doors
Toilet compartment doors shall not swing into the minimum required compartment area....
-
1132A.5.2 Strike edge maneuvering space at doors
The width of the level area on the side to which the door swings shall extend 18 inches (457 mm) past the strike edge for all doors....
- Just Manufacturing Classroom Concealed Ledgemount Teardrop Handle Faucet
- Just Manufacturing Concealed Classroom Faucet with Triple Radius Spout
-
11B-224.1.2 Guest room doors and doorways
Bathrooms doors shall be either sliding or hung to swing in the direction of egress from the bathroom. [2010 ADA Standards] 224.1.2 Guest Room Doors and Doorways....
-
604.8.2.2 Doors
Toilet compartment doors shall not swing into the minimum required compartment area....
-
1132A.5.2 Strike edge maneuvering space at doors
The width of the level area on the side to which the door swings shall extend 18 inches (457 mm) past the strike edge for all doors....
-
D2
Other possible solutions are to enlarge the door opening, use a swing clear hinge, or, if a double-leaf door, replace with uneven width doors....
-
M9
. 48-inch minimum by 66-inch minimum clear floor space for toilet 2. 48-inch minimum by 30-inch minimum clear floor space for lavatory 3. 60-inch minimum turning space 4. door swing...
-
11B-604.8.2.2 Doors
Toilet compartment doors shall not swing into the minimum required compartment area....
-
4.23.4 Water Closets
a standard toilet stall complying with 4.17; where 6 or more stalls are provided, in addition to the stall complying with 4.17.3, at least one stall 36 in (915 mm) wide with an outward swinging...
-
Controls
Clear floor space at controls should be located outside the door swing....
-
4.22.4 Water Closets
a standard toilet stall complying with 4.17; where 6 or more stalls are provided, in addition to the stall complying with 4.17.3, at least one stall 36 in (915 mm) wide with an outward swinging...
- Figure 404.2.4.1(k) Maneuvering Clearances at Manual Swinging Doors and Gates: Latch Approach, Push Side with Closer – Drawing from the U.S. Access Board
- Figure 404.2.4.1(i) Maneuvering Clearances at Manual Swinging Doors and Gates: Latch Approach, Pull Side with Closer – Drawing from the U.S. Access Board
-
Clear Floor Space [4.16.2]
28) specifies the amount of space required at an accessible toilet, not the minimum room size, which must also include turning space, clear floor space at other provided fixtures, door swing...
-
RECOMMENDATIONS
Permit rear or floor mounted swing-away grab bars on both sides of the toilet....
-
Toilet Room Configuration
The most common practice among the innovative designs was the placement of the bathroom located in a corner of a resident room with an out-swinging bathroom door oriented at 450 to the resident...
-
11B-405.7.5 Doorways
Where a door swings onto a ramp landing width, additional ramp landing length as specified may be necessary to accommodate a clear level area for the wheelchair user to clear the door swing...
- Environmental Health Network