Section 35.151(i) Curb ramps (Section-by-Section Analysis) Section 35.151(e) on curb ramps in the 1991 rule has been redesignated as § 35.151(i)....
Search Results "Shower Curb"
-
Section 35.151(i) Curb ramps (Section-by-Section Analysis)
-
1c
Is there a 36" wide by 48" long clear floor space directly outside the shower for persons who use wheelchairs to approach and use the shower as shown in Figure 35(a) above?...
-
R304 Curb Ramps and Blended Transitions (Section-by-Section Analysis)
R304 Curb Ramps and Blended Transitions (Section-by-Section Analysis)...
-
1d
Does the 36" x 48" clear floor space directly outside the shower extend at least 12" past the seat wall of the shower to allow for a seat-to-seat transfer from the wheelchair?...
-
4.21.3 SEAT
A seat shall be provided in shower stalls 36 in by 36 in (915 mm by 915 mm) and shall be as shown in Fig. 36....
-
4.8.1 General
Outdoor rinsing showers shall provide a hand-held shower spray unit complying with ABAAS section 608.6....
-
§ 35.151(e)(2)
(2) Facilities with more than 50 beds covered by this section that provide common use bathing facilities shall provide at least one roll-in shower with a seat that complies with the relevant...
-
11B-608.5 Controls
Controls, faucets, and shower spray units shall comply with Section 11B-309.4. Controls and faucets shall allow the user to close and open the water supply....
-
1134A.6 Showers
Showers required to be accessible shall comply with this section....
-
11B-608.2.2.1 Clearance
A 36 inch (914 mm) wide minimum by 60 inch (1524 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment. [2010 ADAS] 608.2.2.1 Clearance....
-
11B-608.2.2.1 Clearance
A 36 inch (914 mm) wide minimum by 60 inch (1524 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment....
-
Outdoor Rinsing Showers
Outdoor showers permit people to rinse off sand, dirt, and debris. They are not intended for bathing....
-
608.2.3 Alternate Roll-In Type Shower Compartments
608.2.3 Alternate Roll-In Type Shower Compartments....
-
D) Curb Ramps at Intersections
Because a town will not be able to install curb ramps at all town streets right away, the town’s plan for curb ramp installation should set priorities for which streets require curb ramps...
-
4.8 Outdoor Rinsing Showers
[See subsections ...]
-
11B-406.3.1 Slope
The running slope of the curb ramp segments shall be in-line with the direction of sidewalk travel. Ramp runs shall have a running slope not steeper than 1:12....
-
11B-406.3.1 Slope
The running slope of the curb ramp segments shall be in-line with the direction of sidewalk travel. Ramp runs shall have a running slope not steeper than 1:12....
-
11B-406.3.1 Slope
The running slope of the curb ramp segments shall be in-line with the direction of sidewalk travel. Ramp runs shall have a running slope not steeper than 1:12....
-
608.5 Controls
Controls, faucets, and shower spray units shall comply with 309.4....
-
11B-406.5.10 Diagonal curb ramps
Diagonal or corner type curb ramps with returned curbs or other well-defined edges shall have the edges parallel to the direction of pedestrian flow....
-
11B-406.5.10 Diagonal curb ramps
Diagonal or corner type curb ramps with returned curbs or other well-defined edges shall have the edges parallel to the direction of pedestrian flow....
-
11B-809.10.6.1 Size
When one or more shower stalls are provided within the same dwelling unit, as least one shower stall shall comply with one of the following: A transfer type shower compartment...